IEEE Commands
Power Supply NGMO
4.00 / 07-2004
5-9
5.4 SENSE command summary
Com-
mand
Parameter
Par. value
Description
Def.
SCPI
:SENSe
[:A]
Channel A /
Channel 1
:SENSe[1]
Channel A /
Channel 1
:SENSe
:B
Channel B /
Channel 2
:SENSe2
Channel B /
Channel 2
:FUNCtion
<CHAR_VAL>
Selects Fetch,
Read, Measure
function type
VOLT
AGE
"VOLTage"
or VOLTage
Static voltage
measurement
"CURRent"
or CURRent
Static current
measurement
"DVMeter" or
DVMeter
Static DVM
measurement
"AVERage"
or AVERage
Average and
sample
measurement
"PEAK" or
PEAK
Peak and sample
measurement
"MIN" or MIN Min and sample
measurement
"HIGH" or
HIGH
High and sample
measurement
"LOW" or
LOW
Low and sample
measurement
"RMS" or
RMS
Rms and sample
measurement
:FUNCtion
?
Queries
measurement
setting
Results:
VOLTAGE
CURRENT
DVMETER
AVERAGE
PEAK
MIN
HIGH
LOW
RMS
:CURRent [:DC]
:RANGe
[:UPPer]
<CHAR_VAL>
Selects expected
current
measurement
range
HIGH
or 5[A]
HIGH or 5[A] 5A
MEDium or
0.5[A]
500mA