Power Supply NGMO
IEEE Commands
5-10
4.00 / 07-2004
Com-
mand
Parameter
Par. value
Description
Def.
SCPI
LOW or
0.005[A]
5mA
AUTO
Auto ranging
MIN
Auto ranging
*
DEFault
5A
MAX
5mA
DISPlay
Sets LCD to:
CURRENT
RANGE
:CURRent [:DC]
:RANGe
[:UPPer]? <CHAR_VAL>
Queries current
range
HIGH
MEDIUM
LOW
AUTO
MIN
AUTO
DEFault
HIGH
MAX
LOW
:MEASure :INTerval
<CHAR_VAL> or
<NUM_VAL>
Sets the measure-
ment interval for
voltage and
current
1
2.00E-03
Measurement
interval = 2 ms
2.00E-01
Measurement
interval = 200 ms
MIN
2 ms
*
DEFault
10 ms
MAX
200 ms
DISPlay
Sets LCD to
STATIC
MEASURE
INTERVAL
:MEASure :INTerval?
<CHAR_VAL>
Queries measure-
ment interval
Results:
2E-3 <=
NUM_VAL <= 0.2
MIN
0.002 ms
DEFault
0.01 ms
MAX
0.2 ms
:AVERage [:COUNt]
<CHAR_VAL> or
<NUM_VAL>
Sets the measure
average count
1
1
Average count = 1
10
Average count =
10
MIN
1
*
DEFault
1
MAX
10