R&S OSP
Instrument Functions
Module Functions
Quick Start Guide 1505.3896.62 - 14
106
Figure 5-48: Block Diagram Module R&S OSP-B158
When the module R&S OSP-B158 is configured within the R&S OSP, a manual
operation of the module can be performed via the OSP Panel. See
chapter 3.3.8
for
details.
For remote control operation and for details on the connector pin assignments, refer to
the operating manual.
5.2.18 RF Switch Module R&S OSP-B142
The module R&S OSP-B142 is designed as a universal RF switch modules using solid
state relay types. Depending on the variant it consists of one, two or three SPDT
switches or of three DP3T switches. All switches can be operated independently from
each other.
The solid state relay allows handling of up to 40 dBm in a frequency range up to
8 GHz.
The relay is a solid state type; i.e. an RF connection is provided from the terminal C
(Common) to the position P2 only with power switched on. When the relay is activated,
the terminal C is connected to position P1.