R&S OSP
Getting Started
Installing the R&S OSP Panel
Quick Start Guide 1505.3896.62 - 14
34
●
The R&S OSP is configured by default to IP address
192.168.48.147
.
This address is to be entered in the OSP Panel application when using the
examples described in the following chapters.
When a static IP address other then the default address is required, it can be changed
using the OSP Panel. See
chapter 3.3.3
3.2 Installing the R&S OSP Panel
The OSP Panel installation setup is available on CD which is part of the R&S OSP
delivery.
The installation setup includes the VISA libraries which are necessary for running the
OSP Panel.
To install the application, proceed as follows:
●
Insert the documentation CD on the disk drive of your computer.
●
Select
the directory “OSP Panel” on the CD, select the file setup.exe and press
the <ENTER> button to start the installation.
●
If the installation is complete, confirm and exit the installation program.
3.3 R&S OSP Panel Functions
The following sections can help you to make efficient use of the OSP Panel, which is
the application for manual control of the R&S OSP120 and may also be used in
connection with the R&S OSP130. The OSP Panel offers the following features:
●
Configuration of the IP address
●
Dialogs to control the different options configured in the R&S OSP
●
Definition of path configurations
●
Direct access to SCPI commands
The following examples are based on the assumption that the IP address has been
obtained dynamically to be 10.33.10.173.
Summary of Contents for OSP-B011
Page 132: ......