R&S OSP
Instrument Functions
R&S OSP Instrument Frame
Quick Start Guide 1505.3896.62 - 14
78
addition to the three slots at the rear side. Two slots therefore can be used for
mounting the options OSP-B011 and/or OSP-B012. See following diagram.
Figure 5-7: Block Diagram R&S OSP120 Var. 12
Installation of Module Panels OSP-B011/-B012
Note that the length of the cable sets OSP-Z010/-Z011/-Z012 is limited for a maximum
offset of one module only. That means if one Module Panel is mounted in the slot A13F
at the OSP front side, a second Module Panel for example can be installed at the OSP
rearside in
any one of the three available slots (offset ≤ 1 slot).
But it is not possible to mount one Module Panel in the slot A12F at the OSP front side
and a second Module Panel at the OSP rearside in slot A11 (offset > 1 slot)!
5.1.4.1 Module Panel R&S OSP-B011
The module OSP-B011 is a panel (1-slot size) prepared to be fitted with up to twelf
coaxial feed-through connectors SMA-female; see below picture.