Modules
R&S
®
OSP
111
User Manual 1178.7100.02 ─ 05
Figure 3-85: Pinout and block diagram of RF switch module R&S
OSP-B121VL
In the module versions with less than 3 SPDT relays, the relays with the highest Kxx
numbers in the range from K11 to K13 are not available.
The control screen representation of the module R&S
, also with three different versions as listed above.
3.37
R&S
OSP-B122 RF Switch Module
Figure 3-86: R&S
OSP-B122
The one-slot
OSP-B122 (order no. 1515.5510.02) consists of 1
electromechanical SP6T relay, frequency range DC to 18
GHz, with internally
terminated SMA (female) connectors.
Note:
56 N
·
cm
for
SMA
connectors.
The terminal port is labeled with C (common), the other relay ports are labeled with
numbers.
The relay type is monostable (or "failsafe open"). Hence, with no voltage applied to the
relay, no RF connection is provided from terminal C to any of the numbered ports. To
establish an RF connection between C and one of the numbered ports, a continuous
voltage must be applied to the corresponding power terminal of the relay.
R&S
OSP-B122 RF Switch Module