"Device"
Selects the switch unit's "Internal Storage" (= default) or an external
USB storage device. An external USB storage device is only availa-
ble, if it is connected to one of the USB ports on the front or rear
panel of the R&S
OSP.
To remove an external USB storage device, use the eject button and
proceed as described in the section
"Filename"
Selects the file you want to import. The firmware offers only suitable
path definition files with the extension "
.path
", although this exten-
sion is not displayed.
If there is no "
.path
" file in the selected storage device, you cannot
select a filename. Instead, the following message is shown: "There
are no files available on the selected storage device."
"Keep existing" Specifies, if the current path definitions in the switch unit's internal
memory are replaced or amended with the imported path definitions.
However, if you import paths that have the same name as existing
paths in the memory, these existing paths are overwritten.
Remote command:
ROUTe:PATH:IMPort
MMEM:LOAD:STATe
Delete Path Export File ← Export/Import Paths
Access: "Path Switching" > "Context Menu" > "Export/Import Paths" > "Delete Path
Export File"
Deletes a selected path definition file. Proceed as described in the section
Remote command:
ROUTe:PATH:DELete[:NAME]
ROUTe:PATH:DELete:ALL