Modules
R&S
®
OSP
80
User Manual 1178.7100.02 ─ 05
●
Position 4:
–
Signal at "HI_F" INPUT pins 1 & 2 is switched to "HI_F4" (pin 5) of OUT3/4
–
Signal at "HI_S" INPUT pins 3 & 4 is switched to "HI_S4" (pin 6) of OUT3/4
–
Signal at "LO_F" INPUT pins 5 & 6 is switched to "LO_F4" (pin 7) of OUT3/4
–
Signal at "LO_S" INPUT pins 7 & 8 is switched to "LO_S4" (pin 8) of OUT3/4
●
Position 5:
–
Signal at "HI_F" INPUT pins 1 & 2 is switched to "HI_F5" (pin 1) of OUT5/6
–
Signal at "HI_S" INPUT pins 3 & 4 is switched to "HI_S5" (pin 2) of OUT5/6
–
Signal at "LO_F" INPUT pins 5 & 6 is switched to "LO_F5" (pin 3) of OUT5/6
–
Signal at "LO_S" INPUT pins 7 & 8 is switched to "LO_S5" (pin 4) of OUT5/6
●
Position 6:
–
Signal at "HI_F" INPUT pins 1 & 2 is switched to "HI_F6" (pin 5) of OUT5/6
–
Signal at "HI_S" INPUT pins 3 & 4 is switched to "HI_S6" (pin 6) of OUT5/6
–
Signal at "LO_F" INPUT pins 5 & 6 is switched to "LO_F6" (pin 7) of OUT5/6
–
Signal at "LO_S" INPUT pins 7 & 8 is switched to "LO_S6" (pin 8) of OUT5/6
The switch unit supplies 28
V to the module, where a voltage controller converts it
down to 12
V, required to supply power to the relays. The [PWR] LED between the
lower output ports shows the status of this power supply.
●
If the LED shows green light, the internal 12
V power supply is OK and the relays
are operational.
●
If the LED is off, there is a problem with the internal power supply. Contact
Rohde
&
Schwarz
Figure 3-39: Representation of the module on the control screen
The shades behind the dialog of relay K1 are there to indicate that the other relays K2,
K3 and K4 are switched synchronously with K1.
For operation, see
R&S
OSP-B108 DC Multiplexer Module