Functions
R&S
®
OSP
162
User Manual 1178.7100.02 ─ 05
●
A remote control module R&S
OSP-B200R was detected, but without a connected
satellite unit R&S
OSP-B200S2
●
No module was detected in a connected satellite unit
"Other Messages" are notifications of events that typically do not interfere with normal
operation, for example:
●
The number or location of connected modules has changed (after a restart)
●
Instead of a released firmware version, the device runs a service version of the
firmware
Check if a device message is relevant for your operation. For information on handling
errors and warnings, refer to
Note:
The "Device Messages" dialog does not show SCPI error messages. To query
SCPI errors, use the remote control commands
.
If there are
errors
, you can select "Mark All As Confirmed" by clicking the button.
If you have confirmed error messages, you can toggle between the following message
display states:
●
Click "Show All Errors" to display also the confirmed error messages
●
Click "Only Show Unconfirmed Errors" to hide confirmed error messages (=
default)
If there are
warnings
, you can select "Delete all temporary warnings" by clicking the
button.
If there are
other messages
, you can select "Delete All Other Messages" by clicking
the button.
To close this dialog and go back, click the "Back" button.
Remote command:
DIAGnostic:SERVice:USER:ERRor?
DIAGnostic:SERVice:USER:WARNing?
Maintenance
Access: "Main" > "Context Menu" > "Maintenance"
Provides functions for
and
.
Main