"Device"
Selects the storage device. Per default, if no external USB storage
device is connected, the storage device is the "Internal Storage",
which is the primary switch unit's flash memory in the SD card slot. If
there is an external USB storage device, it becomes the default stor-
age device.
To save the file on an external USB storage device, connect it to any
of the switch unit's USB ports (front or rear), and select it by its <devi-
cename>, for example "MY-USBSTICK".
After saving, before you remove this USB storage device, return to
the same "Backup Device" dialog. Then once more select the exter-
nal USB storage device in the "Device" selection field and click the
eject button on the right-hand side of it:
The firmware brings up a message to notify you that "The device
'<devicename>' can now be safely removed."
Click "Close" to confirm this message, then remove the USB storage
device.
On your USB storage device, the folder and filename (with exten-
sion
.backup
) of this file is
"
<Drive>:\ospdata\MyDeviceSettings.backup
".
Here,
<Drive>
is the drive letter of the removable medium.
"Filename"
Specifies the filename of your backup file. In the example above, the
filename is "
MyDeviceSettings
".
Remote command:
Restore Device ← Backup/Restore
Access: "Configuration" > "General" tab > "Context Menu" > "Backup/Restore" >
"Restore Device"
Prerequisite: the data of a previously saved
must be available.
Loads a full set of configurations from a selected backup file into the switch unit’s inter-
nal volatile memory. The configurations file includes all available device settings, path
definitions and secondary switch unit definitions (both in physical and virtual mode) and
the virtual module configurations.