RC Commands
R&S
®
OSP
273
User Manual 1178.7100.02 ─ 05
Manual operation:
See
CONFigure:COMPatible[:MODE]
<state>
Enables or disables backward compatibility of some currently available RC commands
with the syntax of previous firmware versions, used for the legacy switch units of the
R&S
OSP1xx
family: R&S
OSP120, R&S
OSP130 and R&S
OSP150.
The query returns the state of the compatibility mode.
Note that both the current and the deprecated RC commands always are interpreted
correctly by the firmware, independent of your compatibility settings. However, a query
like "
ROUTe:CLOSe?
" returns channel setting strings in the format "
F01M01
" with
CONF:COMP
= OFF and in the format "
F01A11
" with
CONF:COMP
= ON.
If the compatibility mode is enabled, the following commands are also available:
●
●
●
Note that some commands behave differently with or without the compatibility mode
enabled. For example,
ROUTe:PATH:DEFine
as a setting accepts both syntax ver-
sions "F01M01" or "F01A11". But as a query,
ROUTe:PATH:DEFine?
, sent without the
compatibility mode enabled, returns the current syntax. On the contrary, with compati-
bility mode enabled, it returns the legacy syntax, described in section
Setting parameters:
<state>
1 | ON
The set of RC commands is extended as listed above for back-
ward compatibility with R&S
OSP1xx legacy switch units.
0 | OFF
The firmware only accepts the standard set of RC commands.
No additional commands are available to provide backward
compatibility.
Example:
Setting
:
CONF:COMP ON
Enables the compatibility mode.
Example:
Query
:
CONF:COMP:MODE?
Return value: 1
The compatibility mode is enabled.
Manual operation:
See
CONFigure:VIRTual[:MODE]
<state>
Activates or deactivates the
. The query returns the state of the virtual
mode.
Setting parameters:
<state>
CONFigure Commands