Remote Control Commands
R&S
®
NGL200/NGM200
168
User Manual 1178.8736.02 ─ 09
DATA:DATA?
................................................................................................................. 168
DATA:DELete
................................................................................................................ 168
DATA:LIST?
...................................................................................................................169
DATA:POINts?
...............................................................................................................169
FLOG:DATA?
.................................................................................................................169
FLOG:SRATe
.................................................................................................................170
FLOG:TRIGgered
...........................................................................................................170
FLOG:FILE:DURation
.....................................................................................................170
FLOG:FILE:TPARtition
....................................................................................................171
FLOG:TARGet
............................................................................................................... 171
FLOG[:STATe]
............................................................................................................... 171
HCOPy:DATA?
.............................................................................................................. 171
HCOPy:SIZE:X?
............................................................................................................ 171
HCOPy:SIZE:Y?
............................................................................................................ 172
LOG[:STATe]
................................................................................................................. 172
LOG:COUNt
.................................................................................................................. 172
LOG:DURation
.............................................................................................................. 173
LOG:FNAMe?
................................................................................................................173
LOG:INTerval
.................................................................................................................173
LOG:MODE
...................................................................................................................174
LOG:STIMe
...................................................................................................................174
LOG:TRIGgered
............................................................................................................ 175
DATA:DATA?
<filepath>
Returns the logging file data of the selected file.
If manual trigger mode (trigger via TRIG function) is used, the logging function has to
be activated. Without activating the logging function in the manual trigger mode, the
instrument is not able to save a logging file internally or on the USB stick.
Parameters:
<filepath>
Filepath of the logging file data.
Example:
DATA:DATA?
"/int/logging/log-20201203T095013.965.csv"
->
#Device,NGL201
#Calibration Ch1,factory
Timestamp,U1[V],I1[A],P1[W]
09:50:14.078,2.0003,0.00007,0.00013
09:50:14.177,2.0003,0.00007,0.00014
09:50:14.278,2.0003,0.00007,0.00014
09:50:14.376,2.0003,0.00008,0.00016
09:50:14.477,2.0003,0.00008,0.00015
09:50:14.575,2.0003,0.00008,0.00017
Usage:
Query only
DATA:DELete
<filepath>
Deletes the specified file from memory.
Data and File Management Commands