Signal generation control
R&S
®
SMW-K52/-K116
46
User Manual 1175.6778.02 ─ 19
Clipping Level
Sets the limit for clipping.
This value indicates at what point the signal is clipped. It is specified as a percentage,
relative to the highest level. 100% indicates that clipping does not take place.
Remote command:
[:SOURce<hw>]:BB:DVB:CLIPping:LEVel
Clipping Mode
Selects the clipping method. The dialog displays a graphical illustration on how this two
methods work.
●
"Vector | i + jq |"
The limit is related to the amplitude | i + q |. The I and Q components are mapped
together, the angle is retained.
●
"Scalar | i | , | q |"
The limit is related to the absolute maximum of all the I and Q values | i | + | q |.
The I and Q components are mapped separately, the angle changes.
Remote command:
[:SOURce<hw>]:BB:DVB:CLIPping:MODE
4.2
Trigger settings
Access:
► Select "Baseband > DVB > Trigger In".
The dialog provides settings to select and configure the trigger, like trigger source
and trigger mode, and to arm or trigger an internal trigger manually. The current
signal generation status is displayed in the header of the dialog together with infor-
mation on the enabled trigger mode. As in the "Marker" and "Clock" dialogs, this
dialog provides also access to the settings of the related connectors.
This section focuses on the available settings.
For information on how these settings affect the signal, refer to section "Basics on ..."
in the R&S
SMW user manual.
Trigger settings