Remote-control commands
R&S
®
SMW-K52/-K116
83
User Manual 1175.6778.02 ─ 19
Parameters:
<DLength>
integer
Range:
1 to 65536
*RST:
5000
Default unit: Bytes
Example:
See
Example "Configuring DVB-S2X signal in CCM mode"
Manual operation:
See
[:SOURce<hw>]:BB:DVB:DVBS|DVBX:BBFRames?
Queries the number of baseband frames.
The number is available for complete transmission of pseudo-random noise (PN) bits
as data source. The number depends on the length of the PN bit sequence, see
Return values:
<BBFrames>
integer
Range:
1 to depends on settings
*RST:
1
Example:
See
Example "Configuring DVB-S2X signal in CCM mode"
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:DVB:DVBS|DVBX:CPNSequence:STATe
<CompletePNSeq>
Activates transmission of the complete sequence of pseudo-random noise bits within
the baseband frame.
Parameters:
<CompletePNSeq>
1 | ON | 0 | OFF
*RST:
0
Example:
See
Example "Configuring DVB-S2X signal in CCM mode"
Manual operation:
See
[:SOURce<hw>]:BB:DVB:DVBS|DVBX:CRC[:STATe]
<State>
Activates generation of CRC32.
Parameters:
<State>
1 | ON | 0 | OFF
*RST:
1
DVB-S2/DVB-S2X system commands