DVB-S2 Configuration and Settings
R&S
®
SMCVB-K168
11
User Manual 1179.1064.02 ─ 03
State
Activates the standard and deactivates all the other digital standards and digital modu-
lation modes in the same path.
Remote command:
Set To Default
Calls the default settings. The values of the main parameters are listed in the following
table.
Parameter
Value
State
Not affected by the "Set to Default"
Remote command:
Save/Recall
Accesses the "Save/Recall" dialog, that is the standard instrument function for saving
and recalling the complete dialog-related settings in a file. The provided navigation
possibilities in the dialog are self-explanatory.
The settings are saved in a file with predefined extension. You can define the filename
and the directory, in that you want to save the file.
See also, chapter "File and Data Management" in the R&S
SMCV100B user manual.
Remote command:
[:SOURce<hw>]:BB:DVBS2:SETTing:CATalog
[:SOURce<hw>]:BB:DVBS2:SETTing:DELete
[:SOURce<hw>]:BB:DVBS2:SETTing:LOAD
[:SOURce<hw>]:BB:DVBS2:SETTing:STORe
CM Mode
Sets the coding and modulation (CM) mode.
General Settings