Getting Started
R&S
®
TSME6
29
User Manual 4900.0033.02 ─ 06
Figure 3-9: LAN cable connected to LAN connectors of 2 R&S
TSME6 devices
1 = LAN cable
3.1.6.3
LTE MIMO setups with four R&S TSME6s
If four R&S TSME6s are connected to one host PC, multiple signals can be received
by four receive antennas and processed in one application. This is useful, for example,
to perform LTE MIMO path measurements or throughput/CQI estimations (in addition
to the results using two R&S TSME6s).
Table 3-3: Required options for sample (minimum) configuration for LTE MIMO measurements with 4
R&S TSME6s
R&S TSME6
Option
1
KxB, LTE (K29), LTE MIMO (K30)
2
none (MIMO extension option R&S
TSME6-K300 installed by default)
3
none (MIMO extension option R&S
TSME6-K300 installed by default)
4
none (MIMO extension option R&S
TSME6-K300 installed by default)
Required Connections
1. Connect the SYNC-cable to the Aux. connectors of all R&S
TSME6 devices in this
setup.
Preparing for use