111 / 136 - EN -
10.5.
ELS cooling system
The automatic cooling system of the ELS Frontloader is a fan for introducing cooling air, which is connected upstream
from the automatic supply air flap.
Figure 27: ELS cooling system
The automatic cooling system is operated and controlled via the control unit.
To do this, the appropriate event function in the particular kiln control system must be selected.
⇒
You must read the relevant instruction manual for the control system carefully!
10.6.
Exhaust air hood
WARNING
Risk of serious personal injury from burns and scalds, in particular of the hands, face (eyes)
and upper body.
⇒
Do not touch the exhaust air hood during the firing process or the cooling phase.
WARNING
Risk of serious personal injury and property damage:
⇒
Only allow work such as the installation of the exhaust air hood to be carried out by
specially trained and authorised personnel.
The kiln can optionally be equipped with an exhaust air hood. If the exhaust air hood has not been installed before the
kiln is delivered, it must be installed after delivery. In this case, the exhaust air hood comes with detailed assembly
instructions.
NOTE
The introduction of cooling air using a fan or similar at firing chamber temperatures of 600°C
and above can damage the insulating material and the heating elements.
⇒
Cold air may only be brought in at a temperature below 600°C.
⇒
When operating a cooling fan, the exhaust air opening must be open.
If the insulation material is damaged in the event of non-observance of the above-mentioned
information, the manufacturer assumes no liability for this.
Automatic supply air flap
ELS cooling system