126 / 136 - EN -
13.10.4.
Position of electrical connections of the heating elements
Position
Description
Remark
Kiln casing:
Back wall
A cover plate is located on the
back wall of the kiln, which
covers the electrical
connections of the heating
elements.
To remove the cover, 2
screws must be removed.
The cover must then be
pushed up and can then be
removed from the front.
Depending on the design, this
cover can be divided into two
parts. In this case, both covers
must be opened and removed
separately.
Tool:
Use appropriate tools for the
fastening material.
Store the fastening material
in a safe place.
Tip: Loosely screw the
fastening material back into
the corresponding thread for
storage.
Note:
Pay attention to a possible
grounding cable attached to
the cover.
Kiln door
There is a grill plate on the kiln
door, which covers the
electrical connections of the
heating elements.
To remove the cover, a screw
must be loosened, 2-3 turns.
The cover must then be
pushed up and can then be
removed from the front.
Tool:
Use appropriate tools for the
fastening material.
Store the fastening material
in a safe place.
Tip: Loosely screw the
fastening material back into
the corresponding thread for
storage.
Note:
Pay attention to a possible
grounding cable attached to
the cover.
Kiln floor
Below the ELS kiln floor, there
is a grill plate that covers the
electrical connections of the
heating elements.
The kiln floor must be fully
extended.
To remove the cover, 2
screws must be removed.
The cover must then be
pushed forward and can then
be removed downwards.
Tool:
Use appropriate tools for the
fastening material.
Store the fastening material
in a safe place.
Tip:
Loosely screw the fastening
material back into the
corresponding thread for
storage.
Note:
Pay attention to a possible
grounding cable attached to
the cover.
Table 37: Position of connections for heating elements
Summary of Contents for ELS 1000 S
Page 136: ...135 136 Notizen Notes ...
Page 137: ...136 136 Notizen Notes ...
Page 138: ...20210521 01 ...