31
ENGLISH
Appendix B: Parameter list
Par. No. Description
Default Unit
01
Kiln power rating
0,0
kW/h
02
< reserved >
0
-
03
Thermocouple Code (S,R,K,J)
-
04
Kiln maximum temperature
1320
°C
05
Proportional range
2 .0
%
06
Integral time
200
s
07
Program delay
0
s
08
Cycle time
30
s
09
Problems during heat-up
1
-
10
Amount of heating zones
1
-
11
Enter ramps as gradient or time
grad
(grad/time)
12
Function of 1st additional switch output
1
-
13
Function of 2nd additional switch output
0
-
14
Function of 3d additional switch output
0
-
Caution!
Incorrect parameters can cause damage to your kiln and firing goods.
Before deciding to change the parameter settings, remember that the user
is responsible for any adverse consequences. Do not change any para-
meters if you are in doubt!
For safety reasons some parameters are locked at factory (such as changing of
Type S/R thermocouple to Type J/K or vice versa) .