WARNING
Connection of the Radar Sensor
RADAR
Connect the radar sensor in the terminals 19-21 and set
the condominium function, bring S01 to 2.
12 13 14 15 16 17 18 19 20 21 22 23
S 01
2
Opening/ Closing in case of emergency
We add this function for START-S12M for emergency open and close even in case of test for installa-
tion. Pay attention that the control unit will exclude the securities
(photocells, barriers, limit switches
etc)
To open or to close press and keep pressed the button STOP and then keep pressed for at least 5
seconds the button OPEN and CLOSE connected to the terminals 17 and 18. This operation will be
easier in case the BOX of the control unit has a keyboard.”