START-UP

To avoid damage of any kind during the start-up process,
please carefully check all points specified below:

suitable connection cable for the respective
interface

mains voltage in conformity with the specification
on the label

Proceed as follows to install the coin changer in the vending machine:

1

Pull the mains plug of the vending machine.

2

Hang up the coin changer in the vending machine using the three
fastening holes in the rear wall (two at the top and one at the
bottom), see figure below.

Summary of Contents for Currenza C2

Page 1: ...rs Inc GmbH Zum Fruchthof 6 D 21614 Buxtehude Phone 49 0 4161 729 0 Fax 49 0 4161 729 115 e mail info nri de www nri24 com Technical Documentation 04 08 Goe Schn G JM Edition1 1 KA C2 GB Installation Guide Coin changer ...

Page 2: ...tectivemeasures All informationaboutthisproductisavailableinInternetatwww nri de DESIGNANDIDENTIFICATION Label Thelabelofthedevicecontainsalldataidentifyingthecoinchanger e g the devicetypeandseries customer specificsettings currencyandcointypes Models The currenza c2 coin changer series includes four models While the housingdimensionsanddesignarethesame adistinctionismadebetween theversionsBlue G...

Page 3: ...Design It em D esignat ion It em D esignat ion 1 Return lever 7 Coin insert funnel 2 Interface connector 8 Display HI 3 Coin validator 9 IrDA interface HI 4 Keys HI 10 Human Interface HI 5 Tube cassette 11 Lever for cassette removal 6 Payout set 1 2 3 4 6 7 8 9 10 11 5 ...

Page 4: ...version The human interface the operating device for the user consists of a keyboardwithsevenkeysandadisplay Fig 2 Control panel for the Blue version Green version ThecontrolpaneloftheGreenversionconsistsofsevenkeysandthree status diagnosisLED Fig 3 Control panel for the Green version ...

Page 5: ...ser interfaceismadeavailableviatheseparatesettingmoduleHENRIorviathe respectivevendingmachine providedthisfunctionissupported Fig 4 Control panel of White version Orange version ApartfromtheadditionalIrDAcommunicationinterfacetheOrangeversion isidenticalwiththeWhiteversion Fig 5 Control panel of Orange version ...

Page 6: ...low suitableconnectioncablefortherespective interface mainsvoltageinconformitywiththespecification on the label Proceedasfollowstoinstallthecoinchangerinthevendingmachine 1 Pullthemainsplugofthevendingmachine 2 Hangupthecoinchangerinthevendingmachineusingthethree fasteningholesintherearwall twoatthetopandoneatthe bottom seefigurebelow ...

Page 7: ...hinewith screws 5 Swivelthecoinvalidatorinagainandletitengage Ensurethatthereisanairgapbetweenthereturnleverof the vending machine and that of the coin changer 6 Connectthecoinchangertothevendingmachineusingthe requiredconnectingcable andalsoconnectanyexternaldevices suchashopperorrecycler tothecoinchanger 7 Ifnecessary connectcoinchangertopowerviathefeeder barrel connector forPCapplication 8 Reco...

Page 8: ... either the c2 setting module option or the vendingmachinefillingfunction Greenversion Fillingofthismodelisinitiatedbypressingthe key Fillingcanalsobe performedbyconnectingthec2 settingmodule seeBlueversion Blue version Fillingiscontrolledviamenufunctions PresstheMENUbuttontoenterthe selectionlevel Thenpresskey Ftoactivatethefillingmode Fillasusual with the tube cassette dismounted Fillingofthetub...

Page 9: ...ey The coin changer is no longer in operatingmode Blueversion themainmenuisdisplayed Activatethefillingmodeby pressingthekeyF Greenversion thegreenLEDflashes Fillingmodeisactivated 2 Removeemptytubecassetteandinsertprefilledcassette Thetube countersaresettothecoinnumbersofthefloatlevels 3 PresstheMENUkey key Blueversion returntothemainmenu AftertheMENUkeyhasbeen pressedagain thecoinchangerchangest...

Page 10: ...ated 2 Insertvalidcoins Therespectivetubecountercountstheacceptedcoins andthecoin changersortstherespectivecointypeintothetubeconfigured accordinglyuntil thefullsensoriscovered ortheconfiguredmaximumnumberofcoinsisreached orthefloatlevelisreached Thereafter thetubecoinsinsertedwill dependingonthesetting eithernotbeacceptedanddirectedintothereturnarea orbe acceptedanddirectedintothecash box Whenall...

Page 11: ...elf explaining plaintextmessages seefigurebelow Fig 7 Example of an error message in the display Green version Errormessagescanonlybeoutputviathevendingmachine ifthefunction issupported thec2 settingmodule option orthethreeLED Quick diagnosis Fig 8 Location of LED in the control panel of the Green version Error No communication with VMC ...

Page 12: ... nly b y a technician yello w f lashing p ro b lems t hat can easily b e so lved b y cust o mer g reen p ermanent lig ht o r f lashing no p ro b lems White version and Orange version Withoutcontrolpanelthebasicversioncanoutputerrormessagesonlyvia the vending machine connected if the function is supported or the c2 settingmodule option ...