10 

 

 

Noted

In  order  to  avoid  failures  and  interference  signal  transmission

we  connect  a 

resistance120Ω

1/4W

  at  the  end  of  the  DMX  connecting  as  below:

                                                                                                                       

 

  The Conversion between 3pin and 5 pin XLR 

If  the output  cable  of    DMX512  controller is the  5PIN,  please  use  1pc  5PIN  to  3PIN 

cable

       

 

 

11. Connecting picture

 

  Light connecting picture

 

Summary of Contents for LED-PAR64-3W90BL-RGBW

Page 1: ...USER MANUAL High Power LED PAR RGB 90 3W LEDs Waterproof Black LED PAR64 3W90BL RGBW ...

Page 2: ...MX controller function 4 Display operation instruction 5 Manual instruction 6 Operating control instruction 7 XRL connection instruction 9 Connection picture 10 Exploded Views 12 illuminance list 13 Problem analyse 14 Technical specification 15 Please read over this manual before operating the light catalogue ...

Page 3: ...color can be independently dimmer fading changes and so on It uses power switch performs low weight and consumption stable capability and long life The built in program includes dimmer strobe eotic gradual change fading and so on International standard DMX 512 signal is requested Packing list LED PAR64 3W90BL RGBW light 1PC waterproof power in out extension cable waterproof DMX in out extension ca...

Page 4: ...nical structure have been received in good condition and appear no damage This light is designed for indoor use working temperature is lower than 40 degree The fixtures maybe mounted in any position provided there is adequate room for ventilation Make sure there are no inflammable and explosive items ornaments in 0 5 meters away Yellow green cabling earthling safety no flicker when the fixture is ...

Page 5: ...3 ...

Page 6: ...roof silicone 1 13 Display platen 1 4 Lens plate 1 14 display 1 5 Lamp panel 1 15 Silica gel tabletting 1 6 bulb holder 1 16 waterproof silicone 7 bracket 1 set 2PCS 17 Bottom base 1 8 Bottom case cover 1 18 wire clip 1 9 Bottom case waterproof silicone 1 19 bumper bracket 1 10 Power supply 1 5 Main Function Protection rating IP65 in door or out door use unique cooling mode natural convection ...

Page 7: ...or Saturation 3CH 0 255 General dimming 0 100 brightness Note In this mode the color represents visible light such as red green yellow blue and so on Color saturation refers to proportion of the main color 100 saturation means it has reached the solid Value refers to the purity of the color brightness 100 is the brightest 4CH Channel DMX Value Control Function Remark 1CH 0 255 R 0 100 2CH 0 255 G ...

Page 8: ...eed 7CH 0 31 Invalid 32 63 From dark to bright Must use CH1 2 3 4 5 otherwise no light From the 8CH start the speed adjustment 64 95 From bright to dark 96 127 From dark bright dark 128 159 RGB Gradient From the 8CH start the speed adjustment 160 191 dark bright dark Automatic 192 223 4 colors jumping change 224 255 Many color mixing jumping change 8CH 0 255 Speed adjust 7CH 7 Display Operation DM...

Page 9: ...and store the current menu option Press UP DOWN to choose a desired menu item Here are the operation details addr DMX mode A001 A512 SLAV slave receive mode CHNd DMX channel 3 4 5 8CH SP built in program speed change model SP00 SP15 SP00 is the fastest Pr Built in program Pr00 Pr15 16 program in all ASC seven colors jumping AS00 AS15 speed adjustable FAdE gradual change model FA00 FA15 speed adjus...

Page 10: ...p glinting DMX channel choosing Operation CHNd mode Press Menu go back to the initial setting Press UP DOWN until shows CHNd Press ENTER to access the menu items to select the screen will now be glinting Press UP DOWN to change the DMX Channel 3CH 4CH 5CH 8CH At last press ENTER to confirm if it delay for 3 seconds DMX channel choosing will be saved and go back to DMX receive mode A001 If your pre...

Page 11: ...ignal lines are longer than 60 meters 20 lamps should increase a signal amplifier Slave he Slave must be set in DMX mode and the address code should be A001 to assure receive the master s signals correctly Only one light can be set as a Master and others are slaves Note This product uses input and output power cord 2 5 m copper core wire power line in series when 220V AC should less than 10lights ...

Page 12: ...ransmission we connect a resistance120Ω 1 4W at the end of the DMX connecting as below The Conversion between 3pin and 5 pin XLR If the output cable of DMX512 controller is the 5PIN please use 1pc 5PIN to 3PIN cable 11 Connecting picture Light connecting picture ...

Page 13: ...11 ...

Page 14: ...m AC INPUT L N E ground Dashboard PCB Aluminum Light Panel 基灯板 LED PCB DSLM 5408 2 控制主板 Control board PCB V R G B W V GND TXD GND 24V SOUND 5V POWER IN MCU IC DSLM 5408 2A K1 K2 K3 K4 DISPLAY GND 24V Power supply switch AC220V 110V V W R B G V ...

Page 15: ...13 12 Exploded views ...

Page 16: ...14 13 illuminance list ...

Page 17: ...er source is normal If not please check if the switch and the transformer has power out Check if the power input of the IC board is normal Check if the cable connect to the display loose Change the main board to see if it is normal Chang the display LED not light When connect to the electricity did the led flash one time If so the power source is normal If not please check if the switch and the tr...

Page 18: ...ge the IC control board Noted only professional persons can do as above 15 Technical Specification Input voltage AC 170V 264V 47 63HZ Output voltage DC48V Consume 300W Lamp Type High Power LED 3W Lamp Spec R 18PCS G 24PCS B 24PCS W 24PCS Control Signal DMX512 master and slaver Control mode stand alone DMX master and slaver Channel 3 4 5 8 CH Function Effect dimmer strobe eotic gradual change Beam ...

Page 19: ...17 Net Weight 13KG 6101 N 23rd Street Suite K McAllen TX 78504 USA e mail info sirs e com Phone 956 522 2006 Fax 956 686 7380 ...