30
E
U
Ambient temp.
T1
-9 ~ 99°C
Actual test value. Error
code P5 shall be displayed
in case of malfunction
F
U
Temp. of solar
thermal
collector
~0 ~ 140°C
Measured value if failure
show P6
G
U
Electronic
expansion valve
step
10 ~ 47
step
N*10 step
H
U
Tank water
setting temp “T
calc”.
(real value)
TS1
11. EXTERNAL SOLAR CONNECTIVITY
11.1. External solar connectivity
The product can be connected to other remote energy systems (solar panels and solar
thermal power). See Fig 14.
Connection and adjustment of the main regulator must be carried out as follows:
1. Parameter no. 14 of the list indicated in point “10.2. Parameter list” must be set by the
installer, setting the number 2 = solar water circulation.
2. Then connect the external circulation pump I max = 5A (No. 15 in Fig 14), as well as the
solar thermosensor (No. 18 in Fig 14) and the flow switch (No. 17 in Fig 14) (optional). If
the flow switch is not present, short-circuit contact FS 17 (Fig. 15).
Fig 14 - Example of connection to the water supply and solar thermal panels (model with heat exchanger)
Summary of Contents for Dalis Pro 200DHW5
Page 52: ...52 NOTES ...
Page 53: ...53 DALIS PRO DOMESTIC HOT WATER HEAT PUMP EN NOTES ...
Page 54: ...54 NOTES ...
Page 55: ...55 DALIS PRO DOMESTIC HOT WATER HEAT PUMP EN NOTES ...