SMART Touch
4
ELECTRIC UNDERFLOOR INSTALLATION
see numbering on diagram
2.
Connect to Power Supply (Live – MAX 230V)
3.
Connect to Power Supply (Neutral – MAX 230V)
4.
Connect to heater(s) (Neutral – MAX 3600W/16
Amps)
5.
Connect to heater(s) (Live – MAX 3600W/16 Amps)
7.
Connect to 1st wire of floor sensor (colour not
important)
8.
Connect to 2nd wire of floor sensor (colour not
important)
HYDRONIC UNDERFLOOR INSTALLATION
see numbering on diagram
2.
Connect to Power Supply (Live – MAX 230V)
3.
Connect to Power Supply (Neutral – MAX 230V)
4.
Connect to wiring centre (Neutral if present – MAX
3600W/16 Amps)
5.
Connect to wiring centre (Switch Live – MAX 3600W/16
Amps)
7.
Connect to 1st wire of floor sensor (colour not important)
8.
Connect to 2nd wire of floor sensor (colour not important)