CENTRAL HEATING INSTALLATION
see numbering on diagram
2.
Connect to Power Supply (Live – MAX 230V)
3.
Connect to Power Supply (Neutral – MAX 230V)
4.
Connect to Boiler circuit (Neutral if present– MAX
3600W/16 Amps)
5.
Connect to Boiler circuit (240V Switch Live – MAX
3600W/16 Amps)
For extra low voltage or volt-free systems a contactor must
be used.
Connecting the thermostat directly to extra low voltage or
volt-free boilers may cause damage to the boiler circuit.
MOUNTING THERMOSTAT
1.
Push excess wire back through the wall box and
insert thermostat back module into wall box
2.
Put fixing screws through mounting holes and
tighten
3.
Ensure that thermostat is straight before tightening
completely
4.
Replace thermostat front housing;
i) align and sit front housing on to hinges,
ii) push lower half of front housing until a
‘click’ is heard.
5.
Ensure front housing is securely fixed
6.
IMPORTANT:
Tighten both retaining screws
SPECIAL INSTALLATION
see numbering on diagram
Master/Relay installation: (connecting 2 thermostats together)
6. Connect to terminal 6 on other thermostat
7. Connect to terminal 7 on other thermostat