background image

SYGMA

INSTRUCTIONS MANUAL

SYGMA DIGITAL ELECTRIC 

WATER HEATER

MOUNTING, INSTALLATION, 

STARTING AND OPERATION

EN

7

Summary of Contents for SYGMA

Page 1: ...SYGMA INSTRUCTIONS MANUAL SYGMA DIGITAL ELECTRIC WATER HEATER MOUNTING INSTALLATION STARTING AND OPERATION EN 7 ...

Page 2: ...e most stringent quality controls in order to comply with the most rigorous requirements for safety Thanks to the OPTIMIZER ENERGY PLUS technology exclusive to the ROINTE SYSTEM the electric water heater achieves the maximum energy saving Before using the SYGMA electric water heater we recommend that you read this instruction manual in order to ensure correct operation IMPORTANT THIS MANUAL SHOULD...

Page 3: ...on 6 1 6 Safety 6 2 USE 7 3 ELECTRONIC CONTROL FUNCTION 8 4 ADVANCED FUNCTIONALITY 13 5 OPTIMIZER ENERGY PLUS 14 6 MAINTENANCE 15 7 CONDITION OF THE GUARANTEE 16 8 DIMENSIONS AND TECHNICAL CHARACTERISTICS 20 ATTENTION IfyouaretheownerofamodelboughtintheUKorÉire pleaserefer ONLYtoitsmanualasthespecificationsofthewaterheatersaredifferent ENGLISH ...

Page 4: ...Placement In order to fix the heater to the wall you will have to use suitable rawlplugs screws or other fittings to support the weight of the heater when it is full 1 3 Location It is essential that the heater is situated as near as possible to the place where hot water is required In this way water temperature loss in the pipework can be avoided Leave a minimum space of Figure 1 Minimum margins ...

Page 5: ...The security fitting drainage outlet MUST be connected to a water drainage pipe that has to have a diameter that is at least equal to the diameter of the pipe connected to the boiler with a continuous inclination open to the atmosphere and with a minimum distance of 20 mm During the warm up time the water expands producing a drip approximately 3 of its capacity during each heating cycle This is no...

Page 6: ...ut the electrical installation In order to ensure this connection the plug comes provided with the relevant contact It is important that the style of any other plug used is the same type as the one provided with the appliance The electrical system of the premises or house must be checked to ensure that it is equipped with an EARTH wire This appliance complies with the regulations on radio electric...

Page 7: ...not play with the product Figure 2 Wiring diagram 2 USE 2 1 Operation Filling Once the heater has been installed open the stop cock Then open the hot water taps When the water begins to come out of them the heater is full Close the taps and check thoroughly that there are no leaks in the installation Do not connect the heater to ...

Page 8: ...ck on Draining In prolonged periods without use and if there is risk of frosts in the premises where it is installed the heater must be drained It is possible to do this using the safety valve In all cases Cut the current Close the tap where water enters the Installation Drain through the safety group using the lever 3 ELECTRONIC CONTROL FUNCTION 3 1 Front panel description The following image sho...

Page 9: ...3 2 1 6 7 5 9 8 NUM FUNCTION 1 PROGRAMMING 2 DAYS OF THE WEEK 3 TIME OF DAY 4 TEMPERATURE SELECTED 5 LOCKING THE CONTROL PANEL 6 COMFORT ECO ANTI FROST MODE 7 MANUAL AUTOMATIC FUNCTION 8 HEATER ELEMENT ON 9 OPTIMIZER ENERGY PLUS FUNCTION ...

Page 10: ... we can access the time and date adjust feature to adjust the time and date of our water heater Pressing the button flashes up the hours minutes and days of the week according to the number of times it is pressed With the buttons and we can alter the current settings To leave the time and date adjust feature wait 30 seconds or press after the date select 3 4 Locking the control panel By pressing t...

Page 11: ...the Manual and Automatic functions When the Manual function is selected the symbol appears on the display When the Automatic function is selected the symbol appears on the display 3 6 1 Manual function This enables you to choose between the COMFORT ECO and ANTI FROST modes of operation changing the temperature as indicated in Section 3 5 ICON MODE TEMPERATURE RANGE COMFORT 55ºC 73ºC ECO 40ºC 54 5º...

Page 12: ...DAY2 DAY3 We can go forwards and backwards using the button and Press to select the day or days that we wish to program 4 Pressing takes us to the hours we wish to program To change the hours use the or buttons The hours selected will show as 0h 1h 2h By pressing the button we can select the mode required hour by hour COMFORT ECO or OFF 5 To finish the programming press or leave it for 30 seconds ...

Page 13: ...e brightness by pushing the same and keys To finish the programming wait for 10 seconds without pressing any buttons 4 ADVANCED FUNCTIONALITY 4 1 ANTI LEGIONNAIRE S DISEASE Our SYGMA is designed with safety in mind and all the anti legionnaires disease regulations are complied with The water heater is automatically set to over 60ºC for at least one hour once a week Whilst this mode is active you w...

Page 14: ...ter is at the user defined target temperature When the water in the tank is not yet at the user defined target temperature indicated on the TFT screen a percentage value is displayed This represents the heating progress towards this target temperature 5 OPTIMIZER ENERGY PLUS This product includes Optimizer Energy Plus Rointe technology to efficiently manage the energy consumption of the water heat...

Page 15: ...iance will be replaced In the Canary Islands the water tank is guaranteed for 3 YEARS In order to guarantee the life of the water heater it is a requirement that the user agrees to an annual inspection of the magnesium anode to check for erosion Where erosion is excessive it should be replaced Our guarantee will be applied with the express condition that the electrical heater has been well install...

Page 16: ...granted by the current commercial guarantee 7 1 What does the Rointe heaters guarantee cover The Guarantee for ROINTE s heaters that we offer as manufacturer covers over a term of two years from the appliance delivery date the repairs made by ROINTE s Official Technical Assistance Service on any faults that exist at the time of the delivery of the heater It will be understood that the appliance al...

Page 17: ...e magnesium anode is made by the Official Technical Assistance Service and it is replaced when there is excessive erosion Remember that while the heater is being repaired or replaced the period during which you can excercise your rights with the seller and those that are offered in addition by ROINTE s heater guarantee will be temporarily suspended until the repaired or substitue heater is deliver...

Page 18: ...lled in a way that allows access for our technicians The user is responsible for any costs and organization required to provide access to the heaters for their repair and or substitution VERY IMPORTANT in order to be covered by this guarantee it is essential that the user can prove to the guarantor s Official Technical Assistance Department the date of purchase by means of the invoice or ticket em...

Page 19: ...rks all of ROINTE s products to remind the consumer of the obligation to separate them on disposal The consumer should contact the local authority or original point of sale to learn more about the correct disposal of this product 7 2 Cancellation of the present guarantee This guarantee will be annulled and therefore without any effect if the heater has been manipulated modified or repaired by unau...

Page 20: ... 1 4 1 9 2 3 PLACEMENT Vertical Vertical Vertical Vertical Vertical WATER INTAKE inches 1 2 1 2 1 2 3 4 3 4 EMPTY WEIGHT kg 18 25 32 44 56 DIMENSIONS mm A 640 860 1 100 900 1 070 B 680 900 1 150 960 1 120 C 404 404 404 580 580 D 404 404 404 580 580 E 420 420 420 620 620 F 120 120 120 178 178 G 340 573 768 595 685 H 130 142 192 250 250 I 470 715 960 845 935 J 160 160 160 235 235 K 350 350 350 350 3...

Page 21: ...ntomera Murcia Spain For new constructions it is essential that you attach the Certificate of First Occupation NB This certificate of Guarantee must be filled in out in full in order to obtain guarantee rights The date of purchase and seller s stamp are compulsory Please attach a copy of your sales invoices In addition for new constructions include the Certificate of First Occupation CERTIFICATE O...

Page 22: ......

Page 23: ...23 LOW CONSUMPTION DIGITAL ELECTRIC WATER HEATER SYGMA ...

Page 24: ...mera Murcia España T 902 158 049 F 968 277 125 SERVICIO TÉCNICO T 902 130 134 sat rointe com www rointe com ROINTE UK Catalyst House 720 Centennial Court Centennial Park Elstree Herts WD6 3SY T 01432 598 019 F 0208 953 5861 SUPPORT T 01432 598 024 support rointe co uk www rointe co uk ...

Reviews: