User's manual
PCS FS Kit
- 3.31 -
System errors
Error code
Message
Solution
1060
Error overflow 1
Contact technical support
1061
Error overflow 2
Contact technical support
1062
Internal error
Contact technical support
1063
Log checksum failure
Contact technical support
1470
Connection timeout ECU /
HMI
Check CAN cable connection between ECU and HMI
1471
Invalid protocol version
debug
Not active on customer release
1472
Invalid protocol version
SW version of ECU and HMI are not compatible. Make
sure that latest SW updates have been correctly
downloaded to ECU and HMI.
This error could occur during the software update if not
all the devices have been updated with the new
software.
In that case it is recommended to update the software
on all devices
1480
Missing connection ECU /
MD
Check CAN cable connection between ECU and DMD.
Check supply cable to ECU.
Check battery voltage
1481
Connection timeout ECU /
MD
Check CAN cable connection between ECU and DMD
1490
Initialize timeout (%1)
Contact technical support
1550
Connection timeout ECU /
remote terminal
Check connection between ECU and remote terminal
1600
Machine taxing position
Machine in taxing position (lifted)
If this is happening when machine is supposed to be
seeding, check cabling and machine position sensor
1610
Pressure sensor failure
Check connection of pressure sensor
1611
Pressure out of range
Adjust PTO speed so that vacuum pressure is within the
range
1612
Pressure range min > max
Check min and max limit setting of pressure so that min
< max
1615
Fan rpm out of range (%1) Adjust PTO speed so that fan rpm is within the range
1616
Fan rpm range min > max
Modify min and max limit settings of Fan rpm so that
min < max
1701
MD protocol error
Update DMD with latest SW and check that addressing
procedure has been correctly completed
1703
Configuration and setup
parameters lost
Machine configuration parameters have been reset to
default.
Check and correct configuration parameters where
applicable
1801
Invalid configuration or
MD address
Check MD fuses.
Addressing procedure of DMD has to be performed
2000
Data checksum
Contact technical support
Summary of Contents for AGRI Mate PCS FS
Page 1: ...PCS FS Installation Operation Maintenance ORIGINAL INSTRUCTIONS ...
Page 7: ......
Page 34: ...Installation PCS FS Kit 2 13 Figure 2 Wiring diagram of the system without alternator ...
Page 36: ...Installation PCS FS Kit 2 15 Figure 2 14 ECU wiring diagram ...
Page 42: ...Installation PCS FS Kit 2 21 This page is intentionally left blank ...
Page 91: ...User s manual PCS FS Kit 3 49 This page is intentionally left blank ...
Page 94: ...Maintenance and Troubleshooting PCS FS Kit 4 3 4 4 SPARE PARTS ...
Page 99: ...Maintenance and Troubleshooting 4 8 PCS FS Kit This page is intentionally left blank ...