ROJONE Pty. Ltd – 61 Aero Rd, INGLEBURN NSW 2565 AUSTRALIA
TEL +61 02 9829 1555 FAX 02 9605 8812 EMAIL sales@rojone.com.au
6
6.3
VEHICLE INTERFACE
6.3.1
VEHICLE INTERFACE Connector
The VEHICLE INTERFACE is a 9 Pin Female D-Sub miniature Connector.
Pin-out and Wire Loom Colors listed below …
PIN Number
FUNCTION
Description
9 RED
+ 12 VDC
Constant Battery Power
Main Vehicle Battery
+12 to +24 Volts
5 BLACK
Ground
Main Vehicle Battery Ground
4 WHITE
Battery Backup
Connect to Backup Battery Po12 VDC
Take Backup Battery Ground to Chassis or
Main Vehicle Battery Ground.
1 BROWN
IGNITION
+12 VDC Power Input from
Accessory Fuse
.
6 PURPLE
INTRUDER
Connect Through
Door Switch
to Ground.
Switch Contact should be Normally Open
7 ORANGE
EMERGENCY
Connect Through
Panic Switch
to Ground.
Switch Contact should be Normally Open
8 YELLOW
Vehicle KILL
Open Collector Output or Ext Relay Drive
NOTE : 100 mA maximum current Sink.
Suitable for connection to vehicle Computer.
Suitable for connection to supplied relays.
2 GREEN
LOCK
Open Collector Output or Ext Relay Drive
NOTE : 100 mA maximum current Sink.
3 BLUE
UNLOCK
Open Collector Output or Ext Relay Drive
NOTE : 100 mA maximum current Sink.
We advise using the external isolating relays provided in the Kit on all outputs.
These relays isolate the vehicle’s electronic systems from the Unit allowing the control of almost any configuration of
vehicle electrical system.
DO NOT CONNECT THE OUTPUTS DIRECTLY TO HIGH CURRENT
SOLENOIDS.
NOTE : Two different connection methods are shown for vehicle engine Kill, for either fuel starvation or ignition
system electrical shutdown. Generally electrical Kill is more direct and immediate. Your installer should be able
to recommend which is the most suitable type of Engine Kill and connection method for your vehicle.
Your Installer should also be consulted as to the best method of connecting to the Central Locking System of
your particular vehicle. One example of Vehicle Lock and Unlock method is also shown.