background image

3

EN

SAFETY

Life is the greatest value. ROKKY is an electrical product. Take care 
of your and your loved ones’ safety. Familiarize yourself with the ba-
sic principles of product use.

1.  Use only a working product. If you notice any external damage, con-

tact an electrician before connecting the device to a power source. 

2.  Before connecting the device, check that the voltage stated on the 

nameplate matches the voltage in the domestic electrical system.

3.  Check regularly that the power cord has not been damaged and that 

it is safe to use.

4.  Remember!

 A damaged cord should only be replaced by a qualified 

specialist. Entrust the exchange to those who have the appropriate 
permissions.

5.  Do not mount a device that is connected to a voltage. 
6. 

Do not allow the heater to be flooded with water under the threat of 

loss of life.

7. 

When standing in a bathtub, paddling pool or barefoot on a wet floor, 

do not touch the device.

8. 

ROKKY is intended for home, office and hotel use.

9.  ROKKY is not intended for use by children or people with limited 

mental performance or who do not have the necessary knowledge 
or experience in the use of similar equipment. In this case, supervi-
sion or appropriate training by persons responsible for their safety 
is necessary.

Summary of Contents for Rokky Heat

Page 1: ...Rokky Heat Assembly and operating manual Download Startup guide to find out how to configure and use the application the Rokky system www rokky co support ...

Page 2: ......

Page 3: ...atural environment is extremely important to you You have chosen ROKKY which reduces CO2 emissions by up to 60 while also saving huge savings on heating Although ROKKY system is extremely intuitive we encourage you to read the basic information about the product You can always write to us or find additional information on our website www rokky co ...

Page 4: ...2 HEATER S TECHNICAL PARAMETERS A mm B mm C mm D mm W 330 330 330 330 900 1200 1490 1800 500 500 500 500 370 670 970 1270 450 550 650 800 B C D A 12 mm biały czarny 50 mm ...

Page 5: ...s safe to use 4 Remember A damaged cord should only be replaced by a qualified specialist Entrust the exchange to those who have the appropriate permissions 5 Do not mount a device that is connected to a voltage 6 Do not allow the heater to be flooded with water under the threat of loss of life 7 When standing in a bathtub paddling pool or barefoot on a wet floor do not touch the device 8 ROKKY is...

Page 6: ...e is installed in a place for other purposes consult the manufacturer The device has been equipped with protection made in 2nd class of protection CLASSE II it also has IPx5 splash protection enabling installation of the device in the second and third zone of the bathroom room drawing 0 6 m 0 6 m 0 6 m 2 4 m 2 25 m 0 1 2 3 ...

Page 7: ...types of walls If the walls of the room are made of wood or the surface of the room is covered with wallpaper with a foam base a special insu lating pad should be inserted between the wall of a given room and the frame of the device Warning The device should not be installed in the imme diate vicinity of openings or devices controlling ventilation and air conditioning and below electrified power s...

Page 8: ...TRUCTION Aluminum radiator body Control Panel Class II power cord depending on version with or without plug Radiator control module Power switch Mounting console mounting locations Front Back A A B B C C E E D D F F ...

Page 9: ...y tools such as a spirit level drill pencil tape measure screwdriver In order to make the proper installation you will need the appropriate dowels and screws adapted to the type of wall you have Warning The device must not be live during installation Unplug the power plug Familiarize yourself with the safety rules ...

Page 10: ...8 1 2 4x Dimensions see table on page 2 D C ...

Page 11: ...9 EN 3 4 ...

Page 12: ...10 Warning Make sure that the radiator slings are securely at tached to the screws coming out of the wall and the con nection itself prevents the radiator from being accidentally removed from the wall 5 ...

Page 13: ... va lue indicated on the nameplate 2 Plug in the cable which connects the electric cable to the mains socket Any modifications to the connecting cable are forbidden If you have a version with a power cord without a plug connecting the heater to the mains can only be done by a qualified installer 3 The junction box or mains socket must be installed at least 10 cm above the floor In rooms with high ...

Page 14: ...12 The device is equipped with a mechanical on off switch which is located at the back of the heater at the outgoing cable Before swit ching on check that the switch is in the right place ...

Page 15: ...adiator has a full range of its functionality only in Internet connection mode Before switching on the heater download the ROK KY app from APP STORE or GOOGLE PLAY install it on your phone or tablet and follow the instructions displayed on the screen Before you start the configuration make sure that you have a working WiFi router in the apartment and that the radiator is within its range ...

Page 16: ...r key changes the heater power output In the local state the diodes indicate the heating power level of the radiator It is possible to set 11 ranges of heating power The heater heats up periodically depending on the set level of heating For example if the radiator is set to approx 50 of the heating power it means that it will be heated at full power for about 30 minutes in an hour For a radiator w...

Page 17: ...ys While the TIME BOOSTER mode is operating a single LED will flash After the specified time has elapsed the heater will return to its original heating setting In the remote mode the function is available only for rooms specified in the application as bathroom To restore the radiator s factory settings press button located on the radiator control panel for 30 seconds Performing this function will ...

Page 18: ...y white light in the LOCAL mode by orange light ERRORS Damage to the thermal protection The LED system blinks alternately with orange light Overheating The LED system blinks alternately with orange light Loss of connection to a wireless network The radiator goes into local mode with the last setting 11 0 33 22 44 55 77 66 88 100 ...

Page 19: ...d Council of 16 April 2014 on the harmonization of the laws of the Member States relating to the making available on the market of radio equipment and repealing Di rective 1999 5 EC 2009 125 EC Commission Regulation EU 2015 1189 of 28 April 2015 Implementing Directive 2009 125 EC of the European Parlia ment and of the Council with regard to the ecodesign requirements for solid fuel boilers Conform...

Page 20: ...o ve documents authorizes the Manufacturer to refuse to accept the complaint The warranty service covers all defects of the product caused by the fault of the Manufacturer after its delivery or occurred during its use with the exception of transport damage storage damages the radiator accepted for storage is conside red free from defects except for hidden defects found after unse aled and undamage...

Page 21: ...redict and to prevent eg atmospheric events disturbances in electrical in stallations war natural disasters MAINTENANCE We recommend keeping the radiator clean Cleaning can be carried out with a damp cloth without the use of detergents To keep your device in good condition you should do these things regularly The radiator surface must not be painted with any paint or varnish ...

Page 22: ...nents and improper storage and processing of such equipment According to the regulations in force the electric appliance that your ROKKY radiator is purchased can not be placed together with other wastes because it is subject to utilization To dispose of used equipment refer to the point of sale where you pur chased the product The Seller in the light of applicable law is obliged to accept the pro...

Page 23: ...Producer Rokky Sp z o o www rokky co support rokky co ...

Page 24: ...v 200313 JR ...

Reviews: