background image

7

Specifications

Voltage…………………………….…..2 X 3VDC
Typical average standby current……………25µA
Typical test current…………………………2mA
Typical alarm current………………………70mA
Battery life…………………………… 1year (min)
Battery type…………...……………….3V lithium,
……………………...Duracell

®

 DL123A, MN1500

…………………..Sanyo

®

 and Panasonic

®

 CR123A

…………………………..Eveready

®

 energizer E91

Low battery threshold…low battery signal at 2.70V
Sounder…………………….85dB at 10 feet (3.3m)
Low battery beep rate……...1 every 30 sec. + 2 sec.

Sensitivity………………………………2.3%+0.8%/ft
Operating temperature….……40º-100ºF (4.4º-37.8ºC)
Operating humidity……….....0-95% non-condensing
Color……………………………………………..white
Alarm dimensions………..5.5” x 2.3” (14cm x 5.6cm)
Base dimensions……4.88” x 0.38” (12.3cm x 0.95cm)
Drift compensation adjustment………..0.5%/ft. max
Listings……………………………CE, UL217, CSFM
Radioactivity………………Contains NO radioactivity
Transmitter Characteristics:
Nominal center frequency: 433.92MHz – 318MHz
Supervision Transmission: every 65 min.
A compatible receiver: ROKONET’S NOVA
PROGRAMMABLE RECEIVERS

In order to continue improving its product, Rokonet reserves the right to change specifications and/or designs
without any prior notice.

USA

UK

ITALY

FRANCE

BRAZIL

ISRAEL

Rokonet Industries, Inc.
Tel:  +1-914-592-1068
Fax: +1-914-592-1271
e-mail: sales@rokonetusa.com

Rokonet U.K. Ltd.
Tel:  +44-1527-576-765
Fax: +44-1527-576-816
e-mail: info@rokonet.co.uk

Rokonet Electronics SRL
Tel:  +39-02-392-5354
Fax: +39-02-392-5131
e-mail: info@rokonet.it

Rokonet Electronics SARL
Tel:  +33-155-12-3390
Fax: +33-148-86-3042
e-mail: rokonetfr@aol.com

Rokonet Electronics LTDA.
Tel:  +55-21-496.3544
Fax: +55-21-496.3547
e-mail: rokonet@rokonet.com.br

Rokonet Electronics, Ltd.
Tel:  +972-3-961-6555
Fax: +972-3-961-6584
e-mail: info@rokonet.co.il

http://www.rokonet.com

5INT30EU

Summary of Contents for Nova 30

Page 1: ...for interfacing Alarm Alarm restore Low battery Maintenance alert Visible only Selecting a Location Selecting a suitable location is critical to the operation of smoke alarms This equipment should be...

Page 2: ...nchors provided mount the base 8 Attach the alarm to the mounting base as follows Line up the raised tab on the lip of the alarm with the slot on lip of the mounting base See figure 4 Insert the smoke...

Page 3: ...es until the alarm is serviced Attaching and Removing the Smoke Alarm To remove the smoke alarm from the mounting base grasp the alarm and turn it counterclockwise approximately 15 degrees The smoke a...

Page 4: ...m and discard See Figure 7 5 Blow out or use a soft bristled brush to remove dust and dirt from the smoke chamber base 6 Line the new smoke chamber up with the smoke chamber base and snap down into pl...

Page 5: ...see if undue heat is present If they seem cool brace your foot against the bottom of the door with your hip against the door and one hand against the top edge Open it slightly If a rush of hot air is...

Page 6: ...CH SHALL BE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty WARNING This product shoul...

Page 7: ...Characteristics Nominal center frequency 433 92MHz 318MHz Supervision Transmission every 65 min A compatible receiver ROKONET S NOVA PROGRAMMABLE RECEIVERS In order to continue improving its product...

Reviews: