Installation Manual
15
Keypad Connection
The ORBIT-14 can support up to five keypads. Each keypad consists of five wires
and three terminal blocks (for the connection of zones 7 and 8).
NOTE:
The three terminal blocks are not applicable in a 6
-
LED keypad.
1. Connect four wires (Red, Black, Yellow, Green) from the keypad to the
appropriate terminals on the main panel, according to the wire colours.
2. Each keypad has an additional white wire for the connection of a panic button. To
connect the panic button, use the white wire as (+) and the black wire as (-).
NOTE:
The maximum distance between the panic button and the keypad is 30 meters.
3. Connecting zones 7 and 8: Zones 7 and 8, which are located on the keypads
(except for the 6-LED keypad), are end-of-line supervised. If more than one
keypad is connected to the system and zones 7 or 8 are used, the same zones in
the other keypads must be shorted. Each zone can be used only once, in one of
the keypads.
NOTE:
The short of a parallel zone must be done before powering the system
.
Connecting the J3 SIG IN Connector (Signal in Voice
Mail)
The J3 SIG IN voice connector enables the transfer of audio data between the Voice
module and the phone line. For further instruction on the voice module, refer to the
“Voice Module” documentation supplied with the product.