Digit
Event and Result
1D
Zone 12 Alarm Follow (Pulsed)
1E
Zone 13 Alarm Follow (Latched)
1F
Zone 13Alarm Follow (Pulsed)
20
Zone 14 Alarm Follow (Latched)
21
Zone 14 Alarm Follow (Pulsed)
22
Panic Follow (Latched)
UO is activated immediately when a PANIC alarm is triggered by a violation of a
zone, defined as Panic, or by pressing the keypad’s
[1]
and
[2]
keys simultaneously
for two seconds. UO is deactivated when the system is disarmed.
23
Panic Follow (Pulse)
UO is activated for several seconds when a PANIC alarm is triggered by a violation
of a zone, defined as Panic, or by pressing the keypad’s
[1]
and
[2]
keys
simultaneously for two seconds.
24
Special Emergency Keying Follow (Latched)
UO is activated immediately when pressing the keypad’s
[7]
and
[8]
keys
simultaneously for two seconds. UO is deactivated when the system is disarmed.
25
Special Emergency Keying Follow (Pulsed)
UO is activated for several seconds when pressing the keypad’s
[7]
and
[8]
keys
simultaneously for two seconds.
26
Fire Keying Follow (Latched)
UO is activated immediately when a Fire alarm is triggered by a violation of zone 5,
defined as Fire, or by pressing the keypad’s
[4]
and
[5]
keys simultaneously for two
seconds. UO is deactivated when the system is disarmed.
27
Fire Keying Follow (Pulse)
UO is activated when a Fire alarm is triggered by a violation of zone 5, defined as
Fire, or by pressing the keypad’s
[4]
and
[5]
keys simultaneously for two seconds.
28
User Activated (Toggle)
UO may be activated by the user through the entry of
[*]+[2]+[User Code]+[X
],
where X refers to the Utility Output number.
The first entry of the above sequence activates the UO and causes it to latch in the
opposite of its current state. The system briefly lights the Zone LED corresponding to
the selected UO and produces a single confirming beep. Subsequent entries toggle
the response between ON and OFF.
29
User Activated (Pulse)
UO may be activated by the user through the entry of
[*]+[2]+[User Code]+[X],
where X refers to the Utility Output number.
The entry activates the UO for several seconds (pulse). The system briefly lights the
Zone LED corresponding to the selected UO and produces a single confirming beep.
Subsequent entries repeat this pattern.