Installation Manual
32
Digit
Event and Result
37
Ready Follow NO (Latched)
UO is activated whenever the system is in the ready state.
38
Ready follow NO (Pulsed)
UO is activated for several seconds whenever the system is in the ready state.
39
Ready follow, NC (latched)
UO is deactivated whenever the system is in the ready state.
3A
Ready follow, NC (Pulsed)
UO is deactivated for several seconds whenever the system is in the ready state.
Utility Outputs Default:
Utility Output
Location
Type
UO1 046
04
UO2 047
03
UO3 – UO6
048 - 051
00
Communication Parameters:
Locations 052-055
Locations 052 to 055 allow you to define the manner in which the ORBIT-14
communicates with the Central Station when it reports alarms, restorals, troubles,
openings/closings, and tests.
Locations 054 and 055 allow you define the communication format as defined by the
Central Station (CS).
Dialler Control 1: Location 052
•
First digit
: Determines the number corresponding to the Dialling Method,
Duty Cycle and Central Station retries.
•
Second digit
: Determines the number corresponding to the Redial Wait,
Answering Machine Override and Stop Follow Me authorization.
Comments on Dialler Control 1: (Location 052: 1
st
Digit)
Dialling Method
Duty Cycle
MS Retries
Used to select the dialling
method, Pulsed or DTMF.
When selecting the dialling
method, your choice must be
compatible with the type of
phone service available at
the protected premises.
For pulse dialling method 2
option are available: 10 PPS
(Pulse Per Second) or 20
PPS.
For pulse dialling, choose the
proper dialling duty cycle.
67/33%: Typically used in
European telephone systems.
61/39%: Typically used in USA
telephone systems.
The number of times the
ORBIT-14 redials the Central
Station after failing to establish
a successful communication.
Summary of Contents for ORBiT-14
Page 1: ...Installation Manual...
Page 6: ...Installation Manual vi...
Page 57: ...Notes...
Page 58: ...Notes...