INSTALLER PROGRAMMING MENUS

[4]

CODE

Quick Key

Parameter

Options

[4][1]

Code Maintenance:

 

Grand Master

Arm Only

User Unbypass

Authority Level

Manager

Cleaner

Guard

User

Utility Output Activation

[4][2]

Code Maintenance:
Partition

[4][3]

Code Maintenance:
Grand Master

[4][4]

Code Maintenance:
Installer

[4][5]

Code Maintenance:
Sub Installer

[4][6]

Code Maintenance:

 

1) 4 Digits

Code Length

2) 6 Digits

Wire Gauge

Max Combined Length (BUS) from Panel to Expansion module

24 AWG

(0.5 mm / 0.02inch)

150 meters

492 feet

22 AWG

(0.64mm / 0.025inch)

200 meters

656 feet

20 AWG

(0.8 mm / 0.031inch)

333 meters

1092 feet

19 AWG

(0.9 mm / 0.035inch)

400 meters

1312 feet

Wiring information:

Use the following tables for selecting the correct wire thickness to minimize the power loss and ensure reliable system
operation. Take into account the installations current requirements and the wiring distances involved

Desired Wire Gauge for Detectors Wiring Distances

Max

18 AWG

19 AWG

20 AWG

22 AWG

24 AWG

Current

(1.00mm / 0.04inch)

(0.9 mm / 0.035inch)

(0.8 mm / 0.031inch)

(0.64 mm/ 0.025inch)

(0.5 mm / 0.02inch)

(mA)

Max Run

Max Run

Max Run

Max Run

Max Run

Meters

Feet

Meters

Feet

Meters

Feet

Meters

Feet

Meters

Feet

20mA

1195

3920

945

3100

750

2460

472

1550

296

970

30mA

793

2600

628

2060

500

1640

314

1030

197

646

40mA

597

1960

472

1550

375

1230

236

775

148

485

50mA

478

1568

378

1240

300

984

189

620

118

388

60mA

296

1300

314

1030

250

820

157

515

98

323

70mA

341

1120

270

886

214

703

135

443

84

277

80mA

299

980

237

775

187

615

118

388

74

243

90mA

264

867

209

687

166

547

105

343

66

215

100mA

239

784

189

620

123

492

94

310

59

194

Main Panel Technical Data:

Input Power

16.5 Volts AC @ 40 Volt-Amps (VA) (via integral transformer)

Current Consumption

60 mA, typical / 70 mA, maximum

Rechargeable Standby Battery

12 Volts up to 17 Amp-Hours (AH), typical

Power Outputs:
Auxiliary Power

12 Volts DC @ 600 mA, maximum (from all AUX terminals)

Bell/LS (External) Sounder Output

12 Volts DC @ 900 mA, maximum

Programmable Voltage (Utility) Output

UO1: Relay (programmable output) (3 Amps)
UO2: 500 mA transistor
UO3-UO6: Open Collector, 70 mA, maximum

Cabinet Dimensions

375 mm x 330 mm x 98 mm

Main Board Dimensions

200 mm x 115 mm x 65 mm

Fuses

F3

3.0 A
Battery Power

AUX

Automatic fuse

BELL

Automatic fuse

Technical Data of Expansion Modules:

Module

Current Consumption

Additional Information

8 LED Keypad

32 mA, typical /
72 mA maximum

16 LED Keypad

32 mA, typical /
72 mA maximum

LCD Keypad

75 mA maximum

Proximity LCD

100 mA maximum

Keypad 
8 zone expansion

25 mA, typical /

module

30 mA, maximum

16 zone expansion

27 mA, typical /

module

34 mA, maximum

8,16 wireless zone

12 mA, typical / 

Frequency

868.6-868.7 MHz (narrowband operation in EU)

expansion module

15 mA, maximum

Receiving Range: 200 m (Key fob) - 400 m (detectors)

4 relay output

25 mA, typical / 

Contacts: 4 Form C (SPDT) Relays.

expansion module

140 mA, maximum

Contact rating: 3 A / 24V DC

8 transistor output

25 mA, typical / 

Contacts:

 Open Collector, Active Pull-Down, 70 mA maximum

expansion module

30 mA, maximum

Power Supply

Input Power:

16.5 Volts AC @ 40 VA (via transformer)

Expansion Module

Rechargeable 
Standby Battery:

12 Volts up to 17 Amp-Hours (AH), typical

Power Outputs:

Auxiliary power: 12 Volts DC @ 600 mA, maximum
Bell/LS (External) Sounder Output: 12 Volts DC @
900 mA, maximum

Fuses: 

F1: Battery power 3.0 A
F2: Auxiliary power 2.0 A
F3

:

 Bell/loudspeaker power 1.0 A

Event Log

25 mA, typical / X

Expansion Module

 30 mA, maximum

Printer Module

7 mA, typical /
10 mA, maximum

X-10 Transmitter

25 mA, typical /

Module

 29 mA, maximum

Access Control

100 mA maximum

Input power

13.8V DC + 10%

Module

Readers
Consumption

5V / 150 mA maximum

Relay

24V DC / 1 A maximum

Voice Module

6 mA, typical/
26 mA maximum

Electronic Key

11 mA, typical /

Reader

 17  mA maximum

Advance Digital

38 mA, typical / 

Audio Signal

Max = 5V pp / Max = 2V

Voice Module

 57 mA maximum

Voice Message Unit

9 mA (standby) / 

Audio Signal

V in max = 2.5V pp / V out max = 4V pp

60 mA (active speaking -
normal volume) /
130 mA (active speaking -
full volume)

RTTE COMPLIANCE STATEMENT

Hereby, Rokonet Electronics Ltd, declares that this control panel (RP128MC0000A, RP140MC0000A, RP116MC0000A),
with wired accessories (including cables) and wireless accessories, is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.

)

[6][7]

Report Codes: Disarm Codes

[6][7][1..5]

Disarm Codes

1) User Disarm

4)  Remote Disarm

2) Keyswitch Disarm

5)  Wireless Button Disarm

3) Auto Disarm

[6][8]

Report Codes: Miscellaneous

[6][8][1..0]

Miscellaneous

1)  Enter Programming

6)  System Reset

2) Exit Programming

7)  Abort 

Alarm

3)  Periodic MS Test

8)  Self Test O.K

4)  Periodic UD Test

9)  Self Test Failure

5)  Call Back Request

10) Cancel Report

[6][9]

Report Codes:
Special communication

[6][0]

Report Codes: Accessory Code

[6][0][1..4]

Accessory Code

1)  Wireless Zone Expander

3)  Wireless Button Battery

2)  Wireless Button Module 

4)  Printer Module

[6]

REPORT CODES

Quick Key

Parameter

Options

[6][1]

Report Codes: Emergency Key

[6][1][1][1..4]

Emergency Key Alarm

1) Auxiliary Emergency

3) Fire

2) Panic

4) Duress

[6][1][2][1..4]

Emergency Key Alarm Restore

1) Auxiliary Emergency

3) Fire

2) Panic

4) Duress

[6][2][1..9]

Report Codes: Zones

1) Alarm

5) Bypass

2) Alarm Restore

6) Zone Tamper

3) Day zone Trouble/ Wireless 

7) Zone Tamper Restore

Zone Supervision

8) Low Battery

4) Day zone Trouble/ Wireless 

9) Low Battery Restore

Zone Supervision Restore

[6][3][1..7]

Report Codes: Accessory Tamper

1) Keypad

5) Wireless Button Accessory

2) Utility Output

6) Wireless Zone Module

3) Power Supply

7) Advanced Voice Module

4) Event Logger

[6][4]

Report Codes: Main Trouble

[6][4][1][1..0]

Main Trouble

1) Low Battery

6) Clock Not Set

2) Bell

7) BUS Fail

3) Phone

8) False Code

4) AC Loss

9) Bell Tamper

5) Aux Fail

0) Box Tamper

[6][4][2][1..0]

Main Trouble Restore

1) Low Battery

6) Clock Not Set

2) Bell

7) BUS 

Fail

3) Phone

8) False 

Code

4) AC Loss

9)  Bell Tamper

5) Aux Fail

0)  Box Tamper

[6][5]

Report Codes: Power
Supply Module Trouble

[6][5][1][1..4]

Trouble Condition

1)  Low Battery

3)  AC Loss

2) Bell

4)  AUX Fail

[6][5][2][1..4]

Trouble Condition Restore

1)  Low Battery

3)  AC Loss

2) Bell

4)  AUX Fail

[6][6]

Report Codes: Arm Codes

[6][6][1..7]

Arm Codes

1)  User Arm

5)  Quick Arm

2)  Keyswitch Arm

6)  Force Arm

3)  Auto Armed

7)  Wireless Button Arm

4) Remote 

Arm

page 9

page 10

[2]

ZONES

Quick Key Parameter

Options

[2][1]

Zones: One By One

[2][2]

Zones: Partitions

[2][3]

Zones: Zone Type

[2][3][ZZ] + [DISARM] +[00-22] 00) Not Used

09) In Entry Follower 18) Exit Termination

01) Exit Entry 1

10) In Instant

19) Latched Keyswitch

02) Exit Entry 2

11) Utility Output Trigger

20) Entry Fo Stay

03) Exit (Open)/Entry

12) Day Zone

21) Keyswitch Delay

04) Entry Follower

13) 24 Hours

22) Latched Keyswitch 

05) Instant

14) Fire

      Delay

06) In Exit Entry 1

15) Panic

07) In Exit Entry 2

16) Special Emergency

08) In Exit (Open)/Entry

17) Pulsed Keyswitch

[2][4]

Zones: Zone Sound

1) Silent

4) Bell + Buzzer

[2][4][ZZ] + [DISARM] +[1-6]

2) Bell Only

5) Door Chime

3) Buzzer Only

6) Bell/Arm Buzzer/Disarm

[2][5]

Zones: Zone Termination

1) Normally Close

3) Double End Of Line

[2][5][ZZ] + [DISARM] +[1-4]

2) End Of Line

4) Normally Open

[2][6]

Zones: Loop Response

1) Normal (400 ms)

05) 0.5 Hour

09) 2.5 Hours

[2][6][ZZ] + [DISARM] +[1-12

]

2) Slow( 1 sec)

06) 1 Hour

10) 3 Hours

3) Fast (10 ms)

07) 1.5 Hours

11) 3.5 Hours

4) Very Fast (1 ms)

08) 2 Hours

12) 4 Hours

Note:

1.The loop response 1 ms (option 4) is usually used for shutters or other devices that 

require very quick responses. This loop response time can be defined only for zones 
located on the zone expander RP128EZ8F00A.

2.The loop response times defined in locations 5 to 12 can be assigned only to zones 1 

to 8 on the Main Panel or to zones located on the zone expander RP128EZ8F00A.

[2][7] 

Zones: Cross Zones

1) None
2) Ordered
3) Not Ordered

[2][8] 

Zones: Zone Labels

[2][9]

Zones: Maintenance

[2][9][1]

Copy to a Zone

[2][9][2]

Delete a Zone

[2][9][3]

Add/Copy Partition

[2][9][4]

Delete a Partition

[2][9][5] 

Wireless Module Calibration

[2][9][6]

Wireless Zone Allocation

[2][9][7] 

Wireless Communication Test

[2][9][8]

Zone Self Test

[2][9][9]

Soak Test

[2][0]

Zones: Miscellaneous

[2][0][1]

Forced Arming

[2][0][2]

Pulsed Count

page 11

page 12

page 13

page 14

page 15

page 16

[3]

UTILITY OUTPUT

Quick Key

Parameter

Options

[3][0]

Utility Output: Follow Nothing

[3][1]

Utility Output:

 

01) Bell Follow

08) Sensors Test

Follow System Event

02) No Telephone Line

09) Voice Module

03) Communication Failure

10) Battery Test

04) Trouble Follow

11) Bell Burglary

05) Ground Pulse

12) Scheduler

06) Low Battery 

13) Digital Reader Communication

07) Ac Loss Follow

14) Switched Auxiliary

[3][2]

Utility Output:

 

01) Ready Follow

08) Duress Follow

15) Stay Follow

Follow Partition Event

02) Alarm follow

09) Buzzer Follow

16) Tamper Follow

03) Arm Follow

10) Chime Follow

17) Disarm Follow

04) Burglary Follow

11) Exit/Entry Follow

18) Bell Follow

05) Fire Follow

12) Fire Trouble

19) Bell Stay Off

06) Panic Follow

13) Day zone Trouble

20) Zone Bypass

07) Special Emergency Follow

14) General Trouble

[3][3]

Utility Output: Follow Zone

01) Zone Follow

03) Arm Follow

02) Alarm Follow

04) Disarm Follow

Note:

  Each utility output can be activated by a group of up to five zones.

[3][4]

Utility Output: Follow Code

[0]

EXIT PROGRAMMING

[9]

ACCESS CONTROL

Quick Key

Parameter

Default

Range

[9][1]

Door Define

[9][1][1]

Partitions

[9][1][2]

Door Time Setting

[9][1][2][1]

Open Delay

4

1-99 sec

[9][1][2][2]

Door Force Delay

NO

YES/NO

[9][1][2][3]

Door Alarm Delay

10

1-99 sec

[9][1][3]

Door Fire Settings

Open

Open/Close

[9][1][4]

Door Input Settings

[9][1][4][1]

Door contact

N.O

N.O/N.C

[9][1][4][2]

Request to Exit Button

N.O

N.O/N.C

[9][1][5]

Door Label

[9][2]

Card Code Position

00

00-37

[9][3]

Special Code

[9][3][1]

Arm Code

99

00-99

Quick Arm Code

98

00-99

[8]

 

MISCELLANEOUS

[8][1]

Miscellaneous:
Wireless Button Parameters

[8][2]

Miscellaneous:
Wireless Button Allocation

[7]

ACCESSORIES

Quick Key

Parameter

Options

[7][1]

Accessories: Add/Delete Module

[7][1][1..9]

Add/Delete Module

1) Keypad

6) Wireless Button

2) Zone Expander

7) Printer Module

3) Utility Output

8) Access Control

4) Power Supply

91) Digital Key Reader

5) Event Log

92) Advanced Digital Voice Module

[7][2]

Accessories: Verify Module

[7][3]

Accessories: Bus Test

[7][4]

Accessories: Bus Scan 

[7][5]

Accessories: Auto Settings

[1]

SYSTEM

Quick Key

Parameter

Default

Range

[1][1]

System: Time Define

[1][1][1]

Exit Entry Delay 1

[1][1][1][1]

Entry Delay 1

30

0-255 sec

[1][1][1][2]

Exit Delay 1

45

0-255 sec

[1][1][2]

Exit Entry Delay 2

[1][1][2][1]

Entry Delay 2

45

0-255 sec

[1][1][2][2]

Exit Delay 2

60

0-255 sec

[1][1][3]

Bell Time Out

04

01-90 min

[1][1][4]

Bell Delay

00

00-90 min

[1][1][5]

Switched Auxiliary Break

10

01-90 sec

[1][1][6]

Wireless Module Times

[1][1][6][1]

Jamming Time

None

None, 10,20,30 sec

[1][1][6][2]

Supervisory (S.V) Time

0

0-7 hours

[1][1][7]

Zone Test Times

[1][1][7][1]

Start Test

HR:00;MIN:00

00-24 Hours, 00-59 Min

[1][1][7][2]

Zone Test Period

00

00-24 Hours

[1][1][8]

AC Off Delay

30

0-255 Min

[1][1][9] 

More Times

[1][1][9][1]

Phone Line Cut Delay 

04

01-20 Min

[1][1][9][2]

Guard Delay 

30

01-99 Min

[1][2]

System: System Control

[1][2][ 01.. 34]

Parameter

Default Parameter

Default Parameter

Default

01) Quick Arm

YES

13) Alarm Zone

NO

25) Engineer Tamper

NO

Expander Cut

02) Quick UO

YES

14) Fire Temporal Alarm

NO

26) Blank Display

NO

03) Allow Bypass

YES

15) Grand Master Code

NO

27) 24 Hour Bypass

NO

04) Quick Bypass

NO

16) Audible Jamming

NO

28) IMQ Install

NO

05) False Code 

NO

17) Technical Tamper

NO

29) Grand Master 

Trouble

Authority/Partition

YES

06) Bell Squawk

YES

18) Technical Reset

NO

30) Double Code

NO

07) Bell 30/10

NO

19) Abort Alarm

NO

31) Disarm Stop 

YES

Follow Me

08) Alarm Phone Cut

NO

20) Summer/Winter Clock

NO

32) Global Follower

YES

09) 3 Minutes Bypass

YES

21) Forced Keyswitch Arming

YES

33) Area

NO

10) Double Verification

NO 

22) Pager

NO

34) Disable Keypad when

NO

Fire Alarm

Auto Disarm exist

11) Audible Panic

NO

23) Arm Pre Warning

YES

12) Buzzer

Bell

NO

24) Low Battery Arm

YES

[1][3]

System: Set Clock

[1][3][1]

System Date

JAN 01 2000 (SAT)

DD MM YYYY (DAY)

[1][3][2]

System Time

00:00

HH:MM

[1][4]

System: Windowing

[1][4][1]

Window Start

HR:00;MIN:00

00-24 Hours, 00-59 Min

[1][4][2]

Window Stop

HR:00;MIN:00

00-24 Hours, 00-59 Min

[1][4][3]

Window Days

All

SUN(Y/N)-SAT(Y/N)

[1][5]

System: Labels

[1][5][0]

Global

Rokonet

12 Characters

[1][5][ 1..8]

Partition 1 — Partition 8

Partition 1 — Partition 8

12 Characters

[1][6]

System: Tamper Sound

Bell/Arm Buzzer/Disarm

1) Silent

2) Bell Only

3) Buzzer Only

4) Bell +Buzzer

5) Bell/Arm 

6) Buzzer/Disarm

[1][7]

System: Default Enable

Yes

[1][8]

System: Service Information

[1][8][1]

Service Name

ProSYS Security

16 Characters

[1][8][2]

Service Phone

System

16 Characters

[1][9]

System: System Version

[5][7][4][ 1-8][3]

Phone Restore Events

Event Default

Event

Default

01) Intruder

YES

06) Bell Trouble

NO

02) Tamper

NO

07) Low Battery 

NO

03) AC Off

NO

08) Wireless Jamming

NO

04) Wireless lost

NO

09) BUS Trouble

NO

05) Wireless Low Battery

NO

[5][8]

Dialer: Alarm Restore

[5][8][1..3]

Alarm Restore

On Bell Time out

1) On Bell Time put
2) Follow Zone
3) At Disarm

[5][9]

Dialer: Periodic test

[5][9][1]

Monitoring Station Test

[5][9][2]

Upload Download Test

[5][0]

Dialer: Auto Codes

[5][0][1]

Contact ID

[5][0][2]

SIA

[5][0][3]

Delete All

[5]

DIALER

Quick Key

Parameter

Default

Range

[5][1]

Dialer: Telephone Numbers

32 characters

[5][1][1]

MS Phone 1

[5][1][2]

MS Phone 2

[5][1][3]

MS Phone 3

[5][1][4]

Remote Upload/Download Phone

[5][2] 

Dialer: Customer Account Number

[5][3]

Dialer: Communication Format

[5][3][1]

Format for MS Phone 1

[5][3][2]

Format for MS Phone 2

[5][3][3]

Format for MS Phone 3

[5][4]

Dialer: Access and ID

[5][4][1]

Access Code

5678

[5][4][2]

ID Code

0001

[5][4][3]

MS Lock

000000

[5][5]

Dialer: Controls

[5][5] [01..14]

Parameter

Default

Parameter

Default

01 MS Enable

YES

08 Call Back Upload/Download

YES

02 Follow Me Enable

YES

09 Auto Batch

NO

03 Upload/Download Enable

YES

10 Answering Machine Override 

YES

04 Call Delay

NO

11 UL Installation

NO

05 Dial Tone Wait

YES

12 Show Kiss Off

NO

06 Call Save

No

13 Show Handshake

NO

07 User Initiated Call

YES

14 Audible Kissoff

NO

[5][6]

Dialer: Parameters

[5][6][1]

Monitoring Station Retries

08

01-15

[5][6][2]

Follow Me Retries

03

01-15

[5][6][3]

Ring to Upload/Download

12

01-15

[5][6][4]

Dial Tone Time

6

1) 6 seconds
2) 9 seconds

[5][6][5]

Redial Wait

30

1) 30 sec
2) 60 sec

[5][6][6]

Dialing Method

DTMF

1) DTMF
2) Pulse @ 20 BPS
3) Pulse @ 10 BPS

[5][6][7]

Pulse Duty Cycle

61/39

1) 67/33
2) 61/39

[5][6][8]

Swinger Shutdown Limit

00

00-15

[5][7]

Dialer: Report Split

[5][7][1] 

Monitoring Station Arm/Disarm

1

s1

 Backup 2

nd

 

1) Do not call
2) Call 1

s1

3) Call 2

nd

4) Call 3

rd

5) Call All
6) 1

s1

 Backup 2

nd

[5][7][2]

Monitoring Station Urgent 

1

s1

 Backup 2

nd

1) Do not call
2) Call 1

s1

3) Call 2

nd

4) Call 3

rd

5) Call All
6) 1

s1

 Backup 2

nd

[5][7][3]

Monitoring Station Non Urgent

1

s1

 Backup 2

nd

1) Do not call
2) Call 1

s1

3) Call 2

nd

4) Call 3

rd

5) Call All
6) 1

s1

 Backup 2

nd

[5][7][4] 

Follow Me

[5][7][4] [1..8][1]

Phone Partition

[5][7][4] [1..8][2]

Phone Event

Event Default

Event

Default

01) Intruder

YES

10) Disarm

NO

02) Fire

YES

11) Bypass

NO

03) Emergency

YES

12) Wireless lost

NO

04) Panic

YES

13) Wireless Low Battery 

NO

05) Tamper

NO

14) Bell Trouble

NO

06) Remote Programming

NO

15) False Code

NO

07) AC Off

NO

16) Low Battery 

NO

08) Duress

YES

17) Wireless Jamming

NO

09) Arm

NO

18) BUS Trouble

NO