INSTALLER PROGRAMMING MENUS
[4]
CODE
Quick Key
Parameter
Options
[4][1]
Code Maintenance:
Grand Master
Arm Only
User Unbypass
Authority Level
Manager
Cleaner
Guard
User
Utility Output Activation
[4][2]
Code Maintenance:
Partition
[4][3]
Code Maintenance:
Grand Master
[4][4]
Code Maintenance:
Installer
[4][5]
Code Maintenance:
Sub Installer
[4][6]
Code Maintenance:
1) 4 Digits
Code Length
2) 6 Digits
Wire Gauge
Max Combined Length (BUS) from Panel to Expansion module
24 AWG
(0.5 mm / 0.02inch)
150 meters
492 feet
22 AWG
(0.64mm / 0.025inch)
200 meters
656 feet
20 AWG
(0.8 mm / 0.031inch)
333 meters
1092 feet
19 AWG
(0.9 mm / 0.035inch)
400 meters
1312 feet
Wiring information:
Use the following tables for selecting the correct wire thickness to minimize the power loss and ensure reliable system
operation. Take into account the installations current requirements and the wiring distances involved
Desired Wire Gauge for Detectors Wiring Distances
Max
18 AWG
19 AWG
20 AWG
22 AWG
24 AWG
Current
(1.00mm / 0.04inch)
(0.9 mm / 0.035inch)
(0.8 mm / 0.031inch)
(0.64 mm/ 0.025inch)
(0.5 mm / 0.02inch)
(mA)
Max Run
Max Run
Max Run
Max Run
Max Run
Meters
Feet
Meters
Feet
Meters
Feet
Meters
Feet
Meters
Feet
20mA
1195
3920
945
3100
750
2460
472
1550
296
970
30mA
793
2600
628
2060
500
1640
314
1030
197
646
40mA
597
1960
472
1550
375
1230
236
775
148
485
50mA
478
1568
378
1240
300
984
189
620
118
388
60mA
296
1300
314
1030
250
820
157
515
98
323
70mA
341
1120
270
886
214
703
135
443
84
277
80mA
299
980
237
775
187
615
118
388
74
243
90mA
264
867
209
687
166
547
105
343
66
215
100mA
239
784
189
620
123
492
94
310
59
194
Main Panel Technical Data:
Input Power
16.5 Volts AC @ 40 Volt-Amps (VA) (via integral transformer)
Current Consumption
60 mA, typical / 70 mA, maximum
Rechargeable Standby Battery
12 Volts up to 17 Amp-Hours (AH), typical
Power Outputs:
Auxiliary Power
12 Volts DC @ 600 mA, maximum (from all AUX terminals)
Bell/LS (External) Sounder Output
12 Volts DC @ 900 mA, maximum
Programmable Voltage (Utility) Output
UO1: Relay (programmable output) (3 Amps)
UO2: 500 mA transistor
UO3-UO6: Open Collector, 70 mA, maximum
Cabinet Dimensions
375 mm x 330 mm x 98 mm
Main Board Dimensions
200 mm x 115 mm x 65 mm
Fuses
F3
3.0 A
Battery Power
AUX
Automatic fuse
BELL
Automatic fuse
Technical Data of Expansion Modules:
Module
Current Consumption
Additional Information
8 LED Keypad
32 mA, typical /
72 mA maximum
16 LED Keypad
32 mA, typical /
72 mA maximum
LCD Keypad
75 mA maximum
Proximity LCD
100 mA maximum
Keypad
8 zone expansion
25 mA, typical /
module
30 mA, maximum
16 zone expansion
27 mA, typical /
module
34 mA, maximum
8,16 wireless zone
12 mA, typical /
Frequency
:
868.6-868.7 MHz (narrowband operation in EU)
expansion module
15 mA, maximum
Receiving Range: 200 m (Key fob) - 400 m (detectors)
4 relay output
25 mA, typical /
Contacts: 4 Form C (SPDT) Relays.
expansion module
140 mA, maximum
Contact rating: 3 A / 24V DC
8 transistor output
25 mA, typical /
Contacts:
Open Collector, Active Pull-Down, 70 mA maximum
expansion module
30 mA, maximum
Power Supply
Input Power:
16.5 Volts AC @ 40 VA (via transformer)
Expansion Module
Rechargeable
Standby Battery:
12 Volts up to 17 Amp-Hours (AH), typical
Power Outputs:
Auxiliary power: 12 Volts DC @ 600 mA, maximum
Bell/LS (External) Sounder Output: 12 Volts DC @
900 mA, maximum
Fuses:
F1: Battery power 3.0 A
F2: Auxiliary power 2.0 A
F3
:
Bell/loudspeaker power 1.0 A
Event Log
25 mA, typical / X
Expansion Module
30 mA, maximum
Printer Module
7 mA, typical /
10 mA, maximum
X-10 Transmitter
25 mA, typical /
Module
29 mA, maximum
Access Control
100 mA maximum
Input power
13.8V DC + 10%
Module
Readers
Consumption
5V / 150 mA maximum
Relay
24V DC / 1 A maximum
Voice Module
6 mA, typical/
26 mA maximum
Electronic Key
11 mA, typical /
Reader
17 mA maximum
Advance Digital
38 mA, typical /
Audio Signal
Max = 5V pp / Max = 2V
Voice Module
57 mA maximum
Voice Message Unit
9 mA (standby) /
Audio Signal
V in max = 2.5V pp / V out max = 4V pp
60 mA (active speaking -
normal volume) /
130 mA (active speaking -
full volume)
RTTE COMPLIANCE STATEMENT
Hereby, Rokonet Electronics Ltd, declares that this control panel (RP128MC0000A, RP140MC0000A, RP116MC0000A),
with wired accessories (including cables) and wireless accessories, is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.
)
[6][7]
Report Codes: Disarm Codes
[6][7][1..5]
Disarm Codes
1) User Disarm
4) Remote Disarm
2) Keyswitch Disarm
5) Wireless Button Disarm
3) Auto Disarm
[6][8]
Report Codes: Miscellaneous
[6][8][1..0]
Miscellaneous
1) Enter Programming
6) System Reset
2) Exit Programming
7) Abort
Alarm
3) Periodic MS Test
8) Self Test O.K
4) Periodic UD Test
9) Self Test Failure
5) Call Back Request
10) Cancel Report
[6][9]
Report Codes:
Special communication
[6][0]
Report Codes: Accessory Code
[6][0][1..4]
Accessory Code
1) Wireless Zone Expander
3) Wireless Button Battery
2) Wireless Button Module
4) Printer Module
[6]
REPORT CODES
Quick Key
Parameter
Options
[6][1]
Report Codes: Emergency Key
[6][1][1][1..4]
Emergency Key Alarm
1) Auxiliary Emergency
3) Fire
2) Panic
4) Duress
[6][1][2][1..4]
Emergency Key Alarm Restore
1) Auxiliary Emergency
3) Fire
2) Panic
4) Duress
[6][2][1..9]
Report Codes: Zones
1) Alarm
5) Bypass
2) Alarm Restore
6) Zone Tamper
3) Day zone Trouble/ Wireless
7) Zone Tamper Restore
Zone Supervision
8) Low Battery
4) Day zone Trouble/ Wireless
9) Low Battery Restore
Zone Supervision Restore
[6][3][1..7]
Report Codes: Accessory Tamper
1) Keypad
5) Wireless Button Accessory
2) Utility Output
6) Wireless Zone Module
3) Power Supply
7) Advanced Voice Module
4) Event Logger
[6][4]
Report Codes: Main Trouble
[6][4][1][1..0]
Main Trouble
1) Low Battery
6) Clock Not Set
2) Bell
7) BUS Fail
3) Phone
8) False Code
4) AC Loss
9) Bell Tamper
5) Aux Fail
0) Box Tamper
[6][4][2][1..0]
Main Trouble Restore
1) Low Battery
6) Clock Not Set
2) Bell
7) BUS
Fail
3) Phone
8) False
Code
4) AC Loss
9) Bell Tamper
5) Aux Fail
0) Box Tamper
[6][5]
Report Codes: Power
Supply Module Trouble
[6][5][1][1..4]
Trouble Condition
1) Low Battery
3) AC Loss
2) Bell
4) AUX Fail
[6][5][2][1..4]
Trouble Condition Restore
1) Low Battery
3) AC Loss
2) Bell
4) AUX Fail
[6][6]
Report Codes: Arm Codes
[6][6][1..7]
Arm Codes
1) User Arm
5) Quick Arm
2) Keyswitch Arm
6) Force Arm
3) Auto Armed
7) Wireless Button Arm
4) Remote
Arm
page 9
page 10
[2]
ZONES
Quick Key Parameter
Options
[2][1]
Zones: One By One
[2][2]
Zones: Partitions
[2][3]
Zones: Zone Type
[2][3][ZZ] + [DISARM] +[00-22] 00) Not Used
09) In Entry Follower 18) Exit Termination
01) Exit Entry 1
10) In Instant
19) Latched Keyswitch
02) Exit Entry 2
11) Utility Output Trigger
20) Entry Fo Stay
03) Exit (Open)/Entry
12) Day Zone
21) Keyswitch Delay
04) Entry Follower
13) 24 Hours
22) Latched Keyswitch
05) Instant
14) Fire
Delay
06) In Exit Entry 1
15) Panic
07) In Exit Entry 2
16) Special Emergency
08) In Exit (Open)/Entry
17) Pulsed Keyswitch
[2][4]
Zones: Zone Sound
1) Silent
4) Bell + Buzzer
[2][4][ZZ] + [DISARM] +[1-6]
2) Bell Only
5) Door Chime
3) Buzzer Only
6) Bell/Arm Buzzer/Disarm
[2][5]
Zones: Zone Termination
1) Normally Close
3) Double End Of Line
[2][5][ZZ] + [DISARM] +[1-4]
2) End Of Line
4) Normally Open
[2][6]
Zones: Loop Response
1) Normal (400 ms)
05) 0.5 Hour
09) 2.5 Hours
[2][6][ZZ] + [DISARM] +[1-12
]
2) Slow( 1 sec)
06) 1 Hour
10) 3 Hours
3) Fast (10 ms)
07) 1.5 Hours
11) 3.5 Hours
4) Very Fast (1 ms)
08) 2 Hours
12) 4 Hours
Note:
1.The loop response 1 ms (option 4) is usually used for shutters or other devices that
require very quick responses. This loop response time can be defined only for zones
located on the zone expander RP128EZ8F00A.
2.The loop response times defined in locations 5 to 12 can be assigned only to zones 1
to 8 on the Main Panel or to zones located on the zone expander RP128EZ8F00A.
[2][7]
Zones: Cross Zones
1) None
2) Ordered
3) Not Ordered
[2][8]
Zones: Zone Labels
[2][9]
Zones: Maintenance
[2][9][1]
Copy to a Zone
[2][9][2]
Delete a Zone
[2][9][3]
Add/Copy Partition
[2][9][4]
Delete a Partition
[2][9][5]
Wireless Module Calibration
[2][9][6]
Wireless Zone Allocation
[2][9][7]
Wireless Communication Test
[2][9][8]
Zone Self Test
[2][9][9]
Soak Test
[2][0]
Zones: Miscellaneous
[2][0][1]
Forced Arming
[2][0][2]
Pulsed Count
page 11
page 12
page 13
page 14
page 15
page 16
[3]
UTILITY OUTPUT
Quick Key
Parameter
Options
[3][0]
Utility Output: Follow Nothing
[3][1]
Utility Output:
01) Bell Follow
08) Sensors Test
Follow System Event
02) No Telephone Line
09) Voice Module
03) Communication Failure
10) Battery Test
04) Trouble Follow
11) Bell Burglary
05) Ground Pulse
12) Scheduler
06) Low Battery
13) Digital Reader Communication
07) Ac Loss Follow
14) Switched Auxiliary
[3][2]
Utility Output:
01) Ready Follow
08) Duress Follow
15) Stay Follow
Follow Partition Event
02) Alarm follow
09) Buzzer Follow
16) Tamper Follow
03) Arm Follow
10) Chime Follow
17) Disarm Follow
04) Burglary Follow
11) Exit/Entry Follow
18) Bell Follow
05) Fire Follow
12) Fire Trouble
19) Bell Stay Off
06) Panic Follow
13) Day zone Trouble
20) Zone Bypass
07) Special Emergency Follow
14) General Trouble
[3][3]
Utility Output: Follow Zone
01) Zone Follow
03) Arm Follow
02) Alarm Follow
04) Disarm Follow
Note:
Each utility output can be activated by a group of up to five zones.
[3][4]
Utility Output: Follow Code
[0]
EXIT PROGRAMMING
[9]
ACCESS CONTROL
Quick Key
Parameter
Default
Range
[9][1]
Door Define
[9][1][1]
Partitions
[9][1][2]
Door Time Setting
[9][1][2][1]
Open Delay
4
1-99 sec
[9][1][2][2]
Door Force Delay
NO
YES/NO
[9][1][2][3]
Door Alarm Delay
10
1-99 sec
[9][1][3]
Door Fire Settings
Open
Open/Close
[9][1][4]
Door Input Settings
[9][1][4][1]
Door contact
N.O
N.O/N.C
[9][1][4][2]
Request to Exit Button
N.O
N.O/N.C
[9][1][5]
Door Label
[9][2]
Card Code Position
00
00-37
[9][3]
Special Code
[9][3][1]
Arm Code
99
00-99
Quick Arm Code
98
00-99
[8]
MISCELLANEOUS
[8][1]
Miscellaneous:
Wireless Button Parameters
[8][2]
Miscellaneous:
Wireless Button Allocation
[7]
ACCESSORIES
Quick Key
Parameter
Options
[7][1]
Accessories: Add/Delete Module
[7][1][1..9]
Add/Delete Module
1) Keypad
6) Wireless Button
2) Zone Expander
7) Printer Module
3) Utility Output
8) Access Control
4) Power Supply
91) Digital Key Reader
5) Event Log
92) Advanced Digital Voice Module
[7][2]
Accessories: Verify Module
[7][3]
Accessories: Bus Test
[7][4]
Accessories: Bus Scan
[7][5]
Accessories: Auto Settings
[1]
SYSTEM
Quick Key
Parameter
Default
Range
[1][1]
System: Time Define
[1][1][1]
Exit Entry Delay 1
[1][1][1][1]
Entry Delay 1
30
0-255 sec
[1][1][1][2]
Exit Delay 1
45
0-255 sec
[1][1][2]
Exit Entry Delay 2
[1][1][2][1]
Entry Delay 2
45
0-255 sec
[1][1][2][2]
Exit Delay 2
60
0-255 sec
[1][1][3]
Bell Time Out
04
01-90 min
[1][1][4]
Bell Delay
00
00-90 min
[1][1][5]
Switched Auxiliary Break
10
01-90 sec
[1][1][6]
Wireless Module Times
[1][1][6][1]
Jamming Time
None
None, 10,20,30 sec
[1][1][6][2]
Supervisory (S.V) Time
0
0-7 hours
[1][1][7]
Zone Test Times
[1][1][7][1]
Start Test
HR:00;MIN:00
00-24 Hours, 00-59 Min
[1][1][7][2]
Zone Test Period
00
00-24 Hours
[1][1][8]
AC Off Delay
30
0-255 Min
[1][1][9]
More Times
[1][1][9][1]
Phone Line Cut Delay
04
01-20 Min
[1][1][9][2]
Guard Delay
30
01-99 Min
[1][2]
System: System Control
[1][2][ 01.. 34]
Parameter
Default Parameter
Default Parameter
Default
01) Quick Arm
YES
13) Alarm Zone
NO
25) Engineer Tamper
NO
Expander Cut
02) Quick UO
YES
14) Fire Temporal Alarm
NO
26) Blank Display
NO
03) Allow Bypass
YES
15) Grand Master Code
NO
27) 24 Hour Bypass
NO
04) Quick Bypass
NO
16) Audible Jamming
NO
28) IMQ Install
NO
05) False Code
NO
17) Technical Tamper
NO
29) Grand Master
Trouble
Authority/Partition
YES
06) Bell Squawk
YES
18) Technical Reset
NO
30) Double Code
NO
07) Bell 30/10
NO
19) Abort Alarm
NO
31) Disarm Stop
YES
Follow Me
08) Alarm Phone Cut
NO
20) Summer/Winter Clock
NO
32) Global Follower
YES
09) 3 Minutes Bypass
YES
21) Forced Keyswitch Arming
YES
33) Area
NO
10) Double Verification
NO
22) Pager
NO
34) Disable Keypad when
NO
Fire Alarm
Auto Disarm exist
11) Audible Panic
NO
23) Arm Pre Warning
YES
12) Buzzer
➔
Bell
NO
24) Low Battery Arm
YES
[1][3]
System: Set Clock
[1][3][1]
System Date
JAN 01 2000 (SAT)
DD MM YYYY (DAY)
[1][3][2]
System Time
00:00
HH:MM
[1][4]
System: Windowing
[1][4][1]
Window Start
HR:00;MIN:00
00-24 Hours, 00-59 Min
[1][4][2]
Window Stop
HR:00;MIN:00
00-24 Hours, 00-59 Min
[1][4][3]
Window Days
All
SUN(Y/N)-SAT(Y/N)
[1][5]
System: Labels
[1][5][0]
Global
Rokonet
12 Characters
[1][5][ 1..8]
Partition 1 — Partition 8
Partition 1 — Partition 8
12 Characters
[1][6]
System: Tamper Sound
Bell/Arm Buzzer/Disarm
1) Silent
2) Bell Only
3) Buzzer Only
4) Bell +Buzzer
5) Bell/Arm
6) Buzzer/Disarm
[1][7]
System: Default Enable
Yes
[1][8]
System: Service Information
[1][8][1]
Service Name
ProSYS Security
16 Characters
[1][8][2]
Service Phone
System
16 Characters
[1][9]
System: System Version
[5][7][4][ 1-8][3]
Phone Restore Events
Event Default
Event
Default
01) Intruder
YES
06) Bell Trouble
NO
02) Tamper
NO
07) Low Battery
NO
03) AC Off
NO
08) Wireless Jamming
NO
04) Wireless lost
NO
09) BUS Trouble
NO
05) Wireless Low Battery
NO
[5][8]
Dialer: Alarm Restore
[5][8][1..3]
Alarm Restore
On Bell Time out
1) On Bell Time put
2) Follow Zone
3) At Disarm
[5][9]
Dialer: Periodic test
[5][9][1]
Monitoring Station Test
[5][9][2]
Upload Download Test
[5][0]
Dialer: Auto Codes
[5][0][1]
Contact ID
[5][0][2]
SIA
[5][0][3]
Delete All
[5]
DIALER
Quick Key
Parameter
Default
Range
[5][1]
Dialer: Telephone Numbers
32 characters
[5][1][1]
MS Phone 1
[5][1][2]
MS Phone 2
[5][1][3]
MS Phone 3
[5][1][4]
Remote Upload/Download Phone
[5][2]
Dialer: Customer Account Number
[5][3]
Dialer: Communication Format
[5][3][1]
Format for MS Phone 1
[5][3][2]
Format for MS Phone 2
[5][3][3]
Format for MS Phone 3
[5][4]
Dialer: Access and ID
[5][4][1]
Access Code
5678
[5][4][2]
ID Code
0001
[5][4][3]
MS Lock
000000
[5][5]
Dialer: Controls
[5][5] [01..14]
Parameter
Default
Parameter
Default
01 MS Enable
YES
08 Call Back Upload/Download
YES
02 Follow Me Enable
YES
09 Auto Batch
NO
03 Upload/Download Enable
YES
10 Answering Machine Override
YES
04 Call Delay
NO
11 UL Installation
NO
05 Dial Tone Wait
YES
12 Show Kiss Off
NO
06 Call Save
No
13 Show Handshake
NO
07 User Initiated Call
YES
14 Audible Kissoff
NO
[5][6]
Dialer: Parameters
[5][6][1]
Monitoring Station Retries
08
01-15
[5][6][2]
Follow Me Retries
03
01-15
[5][6][3]
Ring to Upload/Download
12
01-15
[5][6][4]
Dial Tone Time
6
1) 6 seconds
2) 9 seconds
[5][6][5]
Redial Wait
30
1) 30 sec
2) 60 sec
[5][6][6]
Dialing Method
DTMF
1) DTMF
2) Pulse @ 20 BPS
3) Pulse @ 10 BPS
[5][6][7]
Pulse Duty Cycle
61/39
1) 67/33
2) 61/39
[5][6][8]
Swinger Shutdown Limit
00
00-15
[5][7]
Dialer: Report Split
[5][7][1]
Monitoring Station Arm/Disarm
1
s1
Backup 2
nd
1) Do not call
2) Call 1
s1
3) Call 2
nd
4) Call 3
rd
5) Call All
6) 1
s1
Backup 2
nd
[5][7][2]
Monitoring Station Urgent
1
s1
Backup 2
nd
1) Do not call
2) Call 1
s1
3) Call 2
nd
4) Call 3
rd
5) Call All
6) 1
s1
Backup 2
nd
[5][7][3]
Monitoring Station Non Urgent
1
s1
Backup 2
nd
1) Do not call
2) Call 1
s1
3) Call 2
nd
4) Call 3
rd
5) Call All
6) 1
s1
Backup 2
nd
[5][7][4]
Follow Me
[5][7][4] [1..8][1]
Phone Partition
[5][7][4] [1..8][2]
Phone Event
Event Default
Event
Default
01) Intruder
YES
10) Disarm
NO
02) Fire
YES
11) Bypass
NO
03) Emergency
YES
12) Wireless lost
NO
04) Panic
YES
13) Wireless Low Battery
NO
05) Tamper
NO
14) Bell Trouble
NO
06) Remote Programming
NO
15) False Code
NO
07) AC Off
NO
16) Low Battery
NO
08) Duress
YES
17) Wireless Jamming
NO
09) Arm
NO
18) BUS Trouble
NO