The Sit N’ Stand Concept

User Instructions - Control Unit ECS-2

FRAME ASSEMBLY

Assemble columns Leg system, foot/feet and bar/bars
Make sure that the power cable is correctly secured by slotting it into the groove in the motor housing.

CONNECTING CONTROL UNIT

1. Mount the control unit to the desktop in the desired location.
2. Connect the motor cables
3. Connect the power unit to the control unit and the power outlet
4. Remember to reset the unit on first use

RESETTING UNIT ON FIRST USE

Before the table can be used, the control unit must be reset to establish 
the lowest point of the table. This is achieved by first lowering the table 
as far as it will go. Until this is done, it will not be possible to elevate 
the table.

 

RESETTING AFTER REPLACING CONTROL UNIT

If a control unit is replaced or switched, the new control unit must first be 
reset to establish the lowest point of the table. To do this, press and hold 
the “Up” and “Down” buttons simultaneously for at least 7 seconds and 
then press “Down” to bring the table to the lowest point. The control unit 
will now have registered the lowest point and the table is ready for use. 
Verify correct functionality by elevating the table to the highest point and 
then back to the lowest point.

The control unit

 is equipped with two safety features; the intermittency function and the overheating protection

• 

Intermittency function

 – The intermittency factor of the control unit is 10%, meaning it can be operated for 1 minute after which it must remain  

 

inactive for 9 minutes. If the one-minute limitation is exceeded, the table will become inoperable until the control box resets automatically.

• 

Overheating protection

 – The table will become inoperable if the overheating protection is triggered and will return to operation automati-

cally once the heat has dissipated sufficiently

Speed

 – the speed of the table varies with load (see separate diagram)

Memory function

 – The control unit will retain information regarding the elevation of the table at all times. This information will remain stored even in 

case of power failure or if the power cable is disconnected from the power outlet.

Soft start 

– Progressive acceleration allows for soft starts and stops

RESET UNIT ON FIRST USE

 

1. Lower table to lowest point 

by pressing “Down” button

2. Table is ready to use

RESETTING AFTER REPLACING CON-
TROL UNIT

1. Press and hold “Up” and 

“Down” simultaneously for 7 

seconds

2. Lower table to lowest point 

by pressing “Down” button

3. Table is ready to use