Page 1: ...ROL ERGO Sweden W www rolergo com P 46 36 36 88 80 USER MANUAL Series EE and ECS2 Stroke 670 650 500 470 METRIC ...

Page 2: ...ting guidelines 9 2 4 System configuration example 10 2 5 Adjustments 11 3 ASSEMBLY ADJUSTMENT 11 3 1 Basic functions 12 3 2 Advanced functions Manuel reset 13 4 MAINTENANCE REPAIRS 14 4 1 Cleaning Inspection and Storage 14 4 2 User Maintenance 14 4 3 Repairs 14 4 4 Servicing of double insulated products 16 5 APPENDIX 16 5 1 Accessories Series EE ECS2 16 5 2 Dimensions column system Series EE ECS2...

Page 3: ...r CAUTION These safety messages are listed in order of severity identify the general risks and what actions you are to take to avoid the risks These signal words mean DANGER Indicates an imminent hazardous with a high risk of serious injury or death WARNING Indicates a potentially hazardous situation that if not avoided may could result in serious injury or death CAUTION Indicates a potential haza...

Page 4: ... attachments not recommended by the manufacturer 4 Never operate this table if it has a damaged cord or plug if it is not working proper ly if it has been dropped or damaged or exposed to water In the event of any such event please return the table to a service center for examination and repair 5 Keep the cord away from heated surfaces 6 Never operate the table with the air openings blocked Keep t...

Page 5: ...l components may result in an electrical shock injury or possible death 6 Do not open the power supply unit or handset under any circumstances The power supply and handset contain no serviceable parts 7 Do not modify or make any changes to the power supply handset or other electrical devices 8 During installation repair cleaning or maintenance work the power cable must be disconnected from the out...

Page 6: ...During the raising or lowering of the table there exists a risk of squeezing or pinching between the moving desktop and fixed objects 2 The necessary safety margins depend on the greatest type of injury risk that can be predicted Where possible small pinch points exist i e fingers use at least 2 5 cm 1 inch safety margin and for body or head especially where children may be present use a minimum o...

Page 7: ...e supervised by a person responsible for their safety or have received instructions from that person on how to use the control unit 13 Children must be supervised at all times to ensure that they do not play with the control unit 14 The table may not be used to lift people Do not sit or stand on a table while it is be raised or lowered 15 The table must not be structurally or technically altered o...

Page 8: ... the system communicate internal and know the position of each column If divergence between the columns will be discovered please do a manual reset as listed in section 3 2 1 4 Electrical rating Electrical rating input 100 240 VAC 50 60Hz Output 29V 2 ASSEMBLY ADJUSTMENT 2 1 Assembly Instruction The official assembly instruction will be found with the base components Make sure to ask your desk ven...

Page 9: ...r cables 2 2 Connect the Power Supply to the handset 5 5mm DC power 3 Connect the power supply to the main After a reset homing the table is ready for use connect the power cord to the outlet please do a manual reset homing as section 3 2 The initial reset drive the motors in a slow speed 2 3 Optional mounting guidelines NOTICE When components like Power Supply motor cables or handset shall be dis...

Page 10: ...t fit the outlet have a proper outlet installed by a qualified electrician This product is designed for the voltage indicated on the power supply label No adap ters should be used with this product CAUTION Risk of electrical shock Before you plug in the power cord check the following again The voltage must be as specified on the power supply label When the power cord is plugged in the electrical c...

Page 11: ...user In case of failure or unexpected operation or from maintenance control your vendor and arrange for service by a qualified technician 3 ASSEMBLY ADJUSTMENT To ensure safe operation of the ECS2 control unit please observe the following safety instructions CAUTION Risk of injury and electric shock Keep children away from electric height adjustable desks control units and handset ...

Page 12: ... if you do not intend to use the desk for a longer period 3 1 Basic functions NOTICE You must read the user manual carefully before installing or operating the control unit If chosen handset doesn t fit to this user manual please see actual user manual for actual handset Over load protection If the total load on the equipment is to high you will only be able to drive for 2 seconds The system will ...

Page 13: ...ange its position proceed as follows Press the desktop up button Keep pressing the button until the required desktop height is reached NOTICE The desktop will continue moving upwards until you release the button or the maximum height is reached 3 1 2 Downward desktop movement This function enables you to adjust the desktop downwards To change its position proceed as follows Press the desktop down ...

Page 14: ...ced Unplug the power cord if you do not intend to use the desk for a longer period Do not store table or cables in direct sunlight 4 2 User Maintenance Products are closed units and require no internal maintenance Legs must be inspected at attachment points wires piston rod cabinet and plugs check that legs function cor rectly Inspect legs for loose connections and damaged plugs wires Inspect powe...

Page 15: ...inute of operation must be followed by 9 minutes of inactivity If this limitation is exceeded the table will become inoperable until the control box resets automatically Overheating protection The table will become inoperable if the overheating protection is triggered and will re turn to operation automatically once the heat has dissipated sufficiently Memory function The control system each colum...

Page 16: ...rovided instead of groun ding No grounding means is provided on a double insulated product nor is a means for grounding to be added to the product Servicing a double insulated product requires extreme care and knowledge of the sys tem and is to be done only by qualified service personnel Replacement parts for a double insulated product must be identical to the parts they replace A double insulated...

Page 17: ...upply Length x width x height 152 x 59 x 34 mm 360 gr P N 68002235 Cables Length 1500mm primary side separately item 78 gr P N 68002232 Length 3000mm primary side separately item 133 gr P N 68002233 Length 2000mm secondary side fixed connected to the power supply ...

Page 18: ...8 80 18 5 2 Dimensions column system Series EE ECS2 with 670 650 500 stroke 31 500 stroke 1122 MAX LEVEL WORKTOP MIN LEVEL 500 stroke 622 60 M8x1 25 Fixing holes for crossbar x 4 650 stroke 1235 650 stroke 585 670 strike 1255 31 x 4 670 stroke 585 ...

Page 19: ...ww rolergo com P 46 36 36 88 80 5 3 Dimensions column system Series EE ECS2 with 470 stroke crossbar MIN LEVEL MAX LEVEL WORKTOP M8x1 25 Fixing holes for crossbar 60 647 470 stroke 31 470 stroke 1117 x 4 68006673 A ROL ERGO ...