5. 

MAINTENANCE & REPAIRS

5.1 

Cleaning, Inspection & Storage

Clean the desk stand by wiping it down with a dry microfiber cloth. Never use solvent, 
abrasive or corrosive compounds.

Products must be cleaned at regular intervals to remove dust and dirt and inspected 
for mechanical damage and normal wear and tear. Worn-out parts must be replaced.
Unplug the power cord if you do not intend to use the desk for a longer period.

Do not store desk or cables in direct sunlight.

5.2  User Maintenance

Products are closed units and require no internal maintenance. Columns must be 
inspected at attachment points, wires, cabinet, and plugs, check that columns function 
correctly.

• 

Inspect columns for loose connections and damaged plugs/wires.

• 

Inspect power supply for loose connections and damaged plugs/wires.

• 

The power supply and the handset is sealed and maintenance free.

5.3 Repairs

Check all screws and bolts after the first week of use and tighten screws and bolts 
where necessary to ensure safe operation of the desk. If the desk cannot be raised or 
lowered, check the cable connection between:

• 

The power supply and the motor/motor house (column system).

• 

The handset and the motor/motor house.

• 

The columns/motors.

If the desk still does not operate, the control system may have triggered the 
overheating or duty cycle protection. Please wait for at least 9 minutes and try again 
before proceeding.

If a control unit is replaced, a manual reset is required. Follow the steps as shown in 
section 4.2.

See Appendix for troubleshooting. If the desk is still not operational, please contact 
your vendor for further assistance.

Summary of Contents for Serie Ei - iDrive

Page 1: ...ROL ERGO Sweden W www rolergo com P 46 36 36 88 80 USER MANUAL Series EE ECS Stroke 650 500 470...

Page 2: ...PI BENCH 4 COLUMN 2 STAGE 470 EPI BENCH 4 COLUMN 3 STAGE 650 Are manufactured in conformity with Machine Directive 2006 42 EG partly completed Machine EMC Electromagnetic Compatibility Directive 2014...

Page 3: ...You will find important safety information in a variety of forms Safety messages are preceded by a safety alert symbol and one of three signal words DANGER WARNING or CAUTION These safety messages ar...

Page 4: ...3 1 Assembly Instruction 9 3 2 System Procedure 10 4 OPERATION INSTRUCTIONS 12 4 1 Basic Functions 12 4 2 Manual Reset 14 5 MAINTENANCE REPAIRS 15 5 1 Cleaning Inspection Storage 15 5 2 User Maintena...

Page 5: ...43 dB 43 dB Electrical rating Input Output 100 240VAC 50 60Hz 3 2A 35V 100 240VAC 50 60Hz 3 2A 35V 100 240VAC 50 60Hz 3 2A 35V Duty cycle 1 9 1 9 1 9 Load shall be evenly distributed Speed may vary w...

Page 6: ...f each column 1 4 Before You Start Check for and remove obstacles in path of the desk top Before first use the control unit must register the lowest point of elevation Do reset as section 4 2 Under no...

Page 7: ...d is damaged A damaged cord shall only be changed by authorised personnel Do not expose the power supply handset or other electrical device to water or other liquids including moisture drips splashes...

Page 8: ...between static objects and moving surfaces During the lowering or rising of the desktop the operator must ensure that no person or object risk being harmed by the operation The desk must only be oper...

Page 9: ...Assembly Instruction The official assembly instruction can be found with the base components Make sure to ask your desk vendor for an approved combination of desktop and frame NOTICE Make sure that t...

Page 10: ...t be unplugged during the setup To set up the desk 1 Connect the motor cables to the control unit 8 pin motor connections 2 Connect the handset to the relevant socket at the control unit ECS 3 Connect...

Page 11: ...ch as the power supply bus cable or the handset the strain relieve hook must be pressed before removing the connector When inserting the connector an audible click indicates that the strain relieve ho...

Page 12: ...rating the control unit If chosen handset is not covered this user manual please see separate user manual supplied with the hand set NOTICE The desktop will continue moving upwards until you release t...

Page 13: ...set the desk will stop when the memory position is reached To drive the desk outside the memory position press the up or down button for a minimum of 5 seconds How to set memory end positions 1 Drive...

Page 14: ...ly a reset homing cycle MUST be performed A reset cycle should be made with an evenly distributed weight of approx 45 kg 100 lbs applied on the desk Perform a reset by Simultaneously pressing the up a...

Page 15: ...mns for loose connections and damaged plugs wires Inspect power supply for loose connections and damaged plugs wires The power supply and the handset is sealed and maintenance free 5 3 Repairs Check a...

Page 16: ...nformation regarding the elevation of the desk at all times This information will remain stored even in case of power failure or if the power cable is disconnected from the power outlet 5 4 Servicing...

Page 17: ...17 ROL ERGO Sweden W www rolergo com P 46 36 36 88 80 6 APPENDIX 6 1 Dimensions leg system Series EE ECS with 500 650 stroke...

Page 18: ...18 ROL ERGO Sweden W www rolergo com P 46 36 36 88 80 6 2 Dimensions leg system Series EE ECS with 470 stroke...

Page 19: ...to move Only one column moving Two columns moving at different speeds Do a reset Change the column that is moving faster than the other Only one column moving Change the column that is moving No No Ye...

Page 20: ...ble to drive all the way up or all the way down Something is blocking the table movement Mechanical damage on column Do a reset Do a reset Do a reset Do a reset Remove the obstacle Change the columns...

Page 21: ...bles are connected The green light on the power supply is lit Change the power supply Follow install instructions Change ECS box No Yes No Yes Desk stuck in absolute top or bottom position Do a reset...

Reviews: