background image

- 11 - 

 

 
 

 
 
 
 
 

Guarantee 

 

Associate Engineering Corporation warrants that all ROLAIR compressors will be free of defects 
in  material  and  workmanship  for  a  period  of  twelve  months  from  the  date  of  initial  retail 
purchase, or eighteen months from the date of manufacture, whichever may occur first. 
 
Should any failure to conform to this warranty be reported to the company within said period, 
the  company  shall,  upon  purchaser  shipping  the  compressor  to  our  plant  transportation 
prepaid, correct such nonconformity by suitable repair or, at its option, furnish a replacement 
part F.O.B. our plant. 
 
Associate  Engineering  Corporation  shall  not  be  liable  for  any  unauthorized  repairs, 
replacements,  adjustments  to  the  compressors,  or  the  costs  of  labor  performed  by  the 
purchaser. 
 
This  warranty  is  expressly  in  lieu  of  all  other  warranties  expressed,  implied  or  statutory 
(including, but not limited to, warranties of merchantability and fitness for purpose) and of 
any  other  obligations,  and/or  liabilities  on  the  part  of  Associate  Engineering  Corporation.  
Associate  Engineering  Corporation  neither  assumes  nor  authorizes  any  other  person  to 
assume  for  it  any  other  obligations  or  liability  in  connection  with  or  with  respect  to  any 
compressor. 
 
Associate  Engineering  Corporation  shall  in  no  event  be  liable  neither  for  any  consequential, 
incidental or special damages nor for the improper selection of any compressor for a particular 
application.

 

 

 

Quality 

 
Associate Engineering Corporation is devoted to continual quality control and thorough 
research  of  the  products  we  build.    It  is  our  creed  to  give  you,  the  user,  all  of  the 
experience and engineering available in the production of every piece of equipment we 
produce. 
 

ROLAIR 

for all the newest and finest features that are available for the modern compressor. 

 
 
 
 

 
 

 

 

606 South Lake Street > P.O. Box 346 > Hustisford, WI 53034-0346 > 920.349.3281 > fax 920.349.3691 > www.rolair.com 

Summary of Contents for VT20ST

Page 1: ...T WARNING COMPRESSOR DISCHARGE AIR MAY CONTAIN HYDROCARBONS AND OTHER CONTAMINANTS DO NOT USE DISCHARGE AIR FOR BREATHING RECORD OF PERTINENT INFORMATION Make a expense by including this reference inf...

Page 2: ...until this manual is read and all safety operating instructions are understood By reading and following the instructions contained in this manual you can achieve years of trouble free service from yo...

Page 3: ...causing them to explode or fly apart Do not use air tools or attachments before maximum pressure recommendations Never allowable pressure ratings Do not use compressor to inflate small low pressure ob...

Page 4: ...or Never point the air stream or tools at any point of your body other people or animals Always turn off the air compressor and drain tank pressure completely before attempting maintenance or attachin...

Page 5: ...ff position before plugging in the power cord By moving the lever to the and stop automatically within the settings of the pressure switch which are typically 95 125 PSI Do not attempt to stop the com...

Page 6: ...he pump and check valve after each cycle allowing for easier restarts A brief audible hiss of air at the end of each cycle signifies the valve is working properly A continuous leak at the relief valve...

Page 7: ...IR compressor is our main concern Do not operate or permit anyone else to operate your air compressor until the information contained in this manual is read and completely understood Please contact yo...

Page 8: ...vailable Even the best machinery requires periodic maintenance Please stick to the maintenance schedule and consider the suggestions that follow to keep your compressor in peak condition NOTE Always u...

Page 9: ...ation X Check for Air or Oil Leaks X Clean Exterior of Air Compressor X Check Condition of Vibration Pads X Tighten Retorque Bolts X Check Operation of Safety Valve X Change Compressor Oil X Clean Cha...

Page 10: ...plug crankcase vent Dirty plugged intake filter Clean replace intake filter Worn piston rings Take unit in for service Scored cylinder Take unit in for service Knocking Noise Internal pump problem Ta...

Page 11: ...ory including but not limited to warranties of merchantability and fitness for purpose and of any other obligations and or liabilities on the part of Associate Engineering Corporation Associate Engine...

Page 12: ...ESPIR PI CES Les pi ces de rechange d origine ROLAIR sont vendues l chelle du pays par l interm diaire d un r seau de concessionnaires et de centres de services agr s Veuillez communiquer avec le conc...

Page 13: ...que ce manuel soit lu et les consignes de s curit fonctionnement comprises En lisant et en suivant les consignes contenues dans ce manuel le nouveau compresseur d air offrira des ann es de service sa...

Page 14: ...soupape de s ret et de d charge ou d autres composants qui contr lent la pression du r servoir Ne jamais faire aucun ajustement aux composants qui contr lent la pression du r servoir Ne pas transform...

Page 15: ...ommandes automatiques peut red marrer tout moment et entra ner des blessures corporelles un moment inattendu Toujours d brancher le compresseur d air et purger les r servoirs d air compl tement avant...

Page 16: ...e chaque jour et maintenir les niveaux d huile un niveau appropri Toujours faire fonctionner le compresseur dans une position de niveau s curitaire qui l emp che de basculer ou de tomber pendant l uti...

Page 17: ...ntre 95 et 125 lb po2 Ne pas tenter d arr ter le compresseur en d branchant le cordon d alimentation Pour arr ter d placer simplement le levier la position Off arr t Le levier active une soupape de re...

Page 18: ...une d faillance pr matur e du joint et ou du moteur FICHE DE CONTR LE POUR LE PR D MARRAGE Lire attentivement le manuel de l utilisateur S assurer de bien comprendre tous les avertissements de s curit...

Page 19: ...sous l ensemble r servoir Le fonctionnement sans les coussinets antivibration annulera la garantie 9 VACUER L HUMIDIT DES R SERVOIRS D AIR CHAQUE JOUR L eau est un d riv naturel de l air comprim vacue...

Page 20: ...ntenance tel qu il est indiqu dans le manuel Plusieurs appareils entra nement direct ROLAIR comme les mod les FC1500HBP2 FC1500HS3 et JC10 sont con us pour un cycle de service de 70 contre les surchar...

Page 21: ...r l essai de temps de remplissage X V rifier le fonctionnement des commandes du syst me X X V rifier la pr sence de bosses fuites sur les r servoirs d air X LUBRIFICATION Avant chaque utilisation pren...

Page 22: ...ge ou le bouchon de remplissage d huile le reniflard du carter Filtre d admission sale bloqu Nettoyer remplacer le filtre d admission Joints du piston us s Faire r viser l appareil Cylindre ray Faire...

Page 23: ...et quelque autre obligation et ou responsabilit de la part de Associate Engineering Corporation Associate Engineering Corporation n assume aucune responsabilit ni n autorise aucune autre personne ass...

Page 24: ...artes genuinas de repuesto de ROLAIR se venden en todo el pa s a trav s de una red de distribuidores y centros de servicio autorizados Contacte al distribuidor donde adquiri su compresora de aire o a...

Page 25: ...ora de aire sin antes haber le do y comprendido todas las instrucciones operativas y de seguridad de este manual Mediante la lectura y seguimiento de las instrucciones de este manual podr alcanzar a o...

Page 26: ...controlan la presi n del tanque podr a provocar lesiones graves o la muerte Nunca realice ajustes a los componentes que controlan la presi n del tanque No altere la configuraci n de f brica de la pres...

Page 27: ...utom ticos puede volver a arrancar en cualquier momento y provocar lesiones f sicas cuando menos se espere Siempre desconecte la compresora de aire y drene completamente los tanques de aire antes de t...

Page 28: ...e adecuados Siempre encienda la compresora en una posici n nivelada y segura que evite que se incline o se vuelque durante su uso No la utilice sin un filtro de aire o en un entorno corrosivo Siempre...

Page 29: ...i n que utiliza Consulte la tabla en la p gina 8 3 INTERRUPTOR DE PRESI N La mayor a de las compresoras de aire el ctricas funcionan mediante el uso de un interruptor de presi n Siempre aseg rese de q...

Page 30: ...configuradas con un funcionamiento de arranque y apagado est n equipadas con una v lvula de seguridad del interruptor de presi n Esta v lvula funciona en combinaci n con la v lvula de retenci n del ta...

Page 31: ...spu s de cada uso a fin de combatir la corrosi n interna de los mismos Mantenga cerradas las v lvulas de drenado si va a guardar la compresora durante alg n tiempo ESPECIFICACIONES OPERACI N ADVERTENC...

Page 32: ...ento de servicio al cliente en nuestra f brica si su compresora de aire que normalmente funciona de manera confiable deja de funcionar correctamente a mayor elevaci n MANTENIMIENTO Su nueva compresora...

Page 33: ...l exterior de la compresora de aire X Revisar la condici n de las almohadillas antivibraci n X Ajustar reajustar los pernos X Revisar el funcionamiento de la v lvula de seguridad X Cambiar el aceite d...

Page 34: ...er Filtro de admisi n sucio o tapado Limpie o reemplace el filtro de admisi n Anillos de pist n desgastados Lleve la unidad a reparaci n Cilindro rayado Lleve la unidad a reparaci n Ruido de golpeteo...

Page 35: ...otras las garant as de comerciabilidad y de idoneidad para un fin espec fico y todas las dem s obligaciones y o responsabilidades por parte de Associate Engineering Corporation Associate Engineering...

Reviews: