background image

- 3 - 

 
 

SAFETY WARNINGS 

READ AND UNDERSTAND ALL SAFETY WARNINGS BEFORE USING AIR COMPRESSOR 

Hazard Level 

Potential of Hazard 

How to Avoid Hazard 

 

Risk of Asphyxiation 

Serious injury or death may occur from 
inhaling compressed air.  The air stream may 
contain carbon monoxide, toxic vapors, or 
solid particles. 

Never inhale compressed air directly from the 
pump, receiver, or from a breathing device 
connected to the air compressor. 

Sprayed materials such as paint, stucco, 
insecticides, solvents, etc.  contain harmful 
vapors and poisons that may cause serious 
injury or death if inhaled. 

Operate compressor only in a well-ventilated 
area.  Use a respirator device and follow the 

spray equipment.  Keep compressor at least 
25 feet away from spray equipment.  

Serious injury or death may occur if the 
exhaust from gas-powered small engines is 
inhaled.  Engine exhaust fumes contain 
poisonous, carbon monoxide which is odorless 
and colorless. 

Operate gas-powered compressors only in a 
well-ventilated area.  Avoid inhaling engine 
exhaust fumes, and never run a small gas-
powered engine in a closed building or 
confined area without adequate ventilation. 

 

Risk of Bursting 

Serious injury or death may occur from an air 
tank explosion if the air tanks are not properly 
maintained or if modifications, alterations or 
repairs are attempted to the air receivers. 

Drain air tanks daily or after each use.  Never 
drill into, weld, patch or modify the air tanks.  
If a leak develops, replace the tank 
immediately or replace the entire compressor. 

Serious injury or death may occur if 
modifications are made to the pilot unloader 
valve, pressure switch, safety relief valve or 
other components that control the tank 
pressure. 
 

Never make adjustments to the components 
that control tank pressure.  Do not make 
alterations to the factory operating pressure 
settings.  Check operation of the safety valve 
on a regular basis and never operate without a 
factory approved safety valve. 

Serious injury may occur if accessories or 
attachments are operated above the 

ratings, causing them to explode or fly apart. 
 

Do not use air tools or attachments before 

maximum pressure recommendations.  Never 

allowable pressure ratings.  Do not use 
compressor to inflate small low pressure 
objects such as toys. 

 
 

 
 
 
 
 
 

Risk of Electrocution or 

Electrical Shock 

Serious injury or death could occur if the air 
compressor is not properly grounded. 

Always plug compressor into a properly 
grounded outlet which provides correct 
voltage, proper grounding and adequate fuse 
protection. 

Electrical shock may occur if compressor is 
not properly operated. 
 

Never operate air compressor in wet 

g. Do 

not allow electric cords to lay in water. Do not 
operate with damaged power cord or with 
protective electrical covers removed. Do not 
touch plug with wet hands.  Do not pull on 
electric cord to disconnect from the outlet. 

Serious injury or death may occur if electrical 
repairs are attempted by unqualified 
personnel. 
 

Any electrical repairs or wiring performed on 
this compressor should only be performed by 
authorized service personnel in accordance 
with the National and Local Electric Codes. 

 

Risk of Explosion or Fire 

 

Serious injury or death may result from normal 
electrical sparks that occur within the motor 
and/or pressure switch. 

Always operate compressor in a well-
ventilated area free of combustible materials, 
gasoline, flammable solvents or vapors. 
Always locate compressor at least 20 feet 
away from work area if spraying flammable 
materials. 

Serious injury may occur if a fire is caused by 
overheating due to inadequate ventilation or 
restrictions to any of the compressors 
ventilation openings. 

Never place objects against or on top of an air 
compressor.  Always operate air compressor 

Always operate in a clean, dry and well-
ventilated area. 

Serious injury or death may occur from a fire 
or explosion if spilled gas or vapors come in 
contact with hot engine parts and ignite. 

Never attempt to fill the gas tank while the 
engine is hot or running.  Add fuel outdoors in 
a well-ventilated area.  Do not fill gas tank near 
lit cigarettes or near other sources of ignition. 

WARNING 

The  engine  exhaust  from  this  product 
contains  chemicals  known  to  the  State 
of  California  to  cause  cancer,  birth 
defects or other reproductive harm. 

Summary of Contents for VT20ST

Page 1: ...T WARNING COMPRESSOR DISCHARGE AIR MAY CONTAIN HYDROCARBONS AND OTHER CONTAMINANTS DO NOT USE DISCHARGE AIR FOR BREATHING RECORD OF PERTINENT INFORMATION Make a expense by including this reference inf...

Page 2: ...until this manual is read and all safety operating instructions are understood By reading and following the instructions contained in this manual you can achieve years of trouble free service from yo...

Page 3: ...causing them to explode or fly apart Do not use air tools or attachments before maximum pressure recommendations Never allowable pressure ratings Do not use compressor to inflate small low pressure ob...

Page 4: ...or Never point the air stream or tools at any point of your body other people or animals Always turn off the air compressor and drain tank pressure completely before attempting maintenance or attachin...

Page 5: ...ff position before plugging in the power cord By moving the lever to the and stop automatically within the settings of the pressure switch which are typically 95 125 PSI Do not attempt to stop the com...

Page 6: ...he pump and check valve after each cycle allowing for easier restarts A brief audible hiss of air at the end of each cycle signifies the valve is working properly A continuous leak at the relief valve...

Page 7: ...IR compressor is our main concern Do not operate or permit anyone else to operate your air compressor until the information contained in this manual is read and completely understood Please contact yo...

Page 8: ...vailable Even the best machinery requires periodic maintenance Please stick to the maintenance schedule and consider the suggestions that follow to keep your compressor in peak condition NOTE Always u...

Page 9: ...ation X Check for Air or Oil Leaks X Clean Exterior of Air Compressor X Check Condition of Vibration Pads X Tighten Retorque Bolts X Check Operation of Safety Valve X Change Compressor Oil X Clean Cha...

Page 10: ...plug crankcase vent Dirty plugged intake filter Clean replace intake filter Worn piston rings Take unit in for service Scored cylinder Take unit in for service Knocking Noise Internal pump problem Ta...

Page 11: ...ory including but not limited to warranties of merchantability and fitness for purpose and of any other obligations and or liabilities on the part of Associate Engineering Corporation Associate Engine...

Page 12: ...ESPIR PI CES Les pi ces de rechange d origine ROLAIR sont vendues l chelle du pays par l interm diaire d un r seau de concessionnaires et de centres de services agr s Veuillez communiquer avec le conc...

Page 13: ...que ce manuel soit lu et les consignes de s curit fonctionnement comprises En lisant et en suivant les consignes contenues dans ce manuel le nouveau compresseur d air offrira des ann es de service sa...

Page 14: ...soupape de s ret et de d charge ou d autres composants qui contr lent la pression du r servoir Ne jamais faire aucun ajustement aux composants qui contr lent la pression du r servoir Ne pas transform...

Page 15: ...ommandes automatiques peut red marrer tout moment et entra ner des blessures corporelles un moment inattendu Toujours d brancher le compresseur d air et purger les r servoirs d air compl tement avant...

Page 16: ...e chaque jour et maintenir les niveaux d huile un niveau appropri Toujours faire fonctionner le compresseur dans une position de niveau s curitaire qui l emp che de basculer ou de tomber pendant l uti...

Page 17: ...ntre 95 et 125 lb po2 Ne pas tenter d arr ter le compresseur en d branchant le cordon d alimentation Pour arr ter d placer simplement le levier la position Off arr t Le levier active une soupape de re...

Page 18: ...une d faillance pr matur e du joint et ou du moteur FICHE DE CONTR LE POUR LE PR D MARRAGE Lire attentivement le manuel de l utilisateur S assurer de bien comprendre tous les avertissements de s curit...

Page 19: ...sous l ensemble r servoir Le fonctionnement sans les coussinets antivibration annulera la garantie 9 VACUER L HUMIDIT DES R SERVOIRS D AIR CHAQUE JOUR L eau est un d riv naturel de l air comprim vacue...

Page 20: ...ntenance tel qu il est indiqu dans le manuel Plusieurs appareils entra nement direct ROLAIR comme les mod les FC1500HBP2 FC1500HS3 et JC10 sont con us pour un cycle de service de 70 contre les surchar...

Page 21: ...r l essai de temps de remplissage X V rifier le fonctionnement des commandes du syst me X X V rifier la pr sence de bosses fuites sur les r servoirs d air X LUBRIFICATION Avant chaque utilisation pren...

Page 22: ...ge ou le bouchon de remplissage d huile le reniflard du carter Filtre d admission sale bloqu Nettoyer remplacer le filtre d admission Joints du piston us s Faire r viser l appareil Cylindre ray Faire...

Page 23: ...et quelque autre obligation et ou responsabilit de la part de Associate Engineering Corporation Associate Engineering Corporation n assume aucune responsabilit ni n autorise aucune autre personne ass...

Page 24: ...artes genuinas de repuesto de ROLAIR se venden en todo el pa s a trav s de una red de distribuidores y centros de servicio autorizados Contacte al distribuidor donde adquiri su compresora de aire o a...

Page 25: ...ora de aire sin antes haber le do y comprendido todas las instrucciones operativas y de seguridad de este manual Mediante la lectura y seguimiento de las instrucciones de este manual podr alcanzar a o...

Page 26: ...controlan la presi n del tanque podr a provocar lesiones graves o la muerte Nunca realice ajustes a los componentes que controlan la presi n del tanque No altere la configuraci n de f brica de la pres...

Page 27: ...utom ticos puede volver a arrancar en cualquier momento y provocar lesiones f sicas cuando menos se espere Siempre desconecte la compresora de aire y drene completamente los tanques de aire antes de t...

Page 28: ...e adecuados Siempre encienda la compresora en una posici n nivelada y segura que evite que se incline o se vuelque durante su uso No la utilice sin un filtro de aire o en un entorno corrosivo Siempre...

Page 29: ...i n que utiliza Consulte la tabla en la p gina 8 3 INTERRUPTOR DE PRESI N La mayor a de las compresoras de aire el ctricas funcionan mediante el uso de un interruptor de presi n Siempre aseg rese de q...

Page 30: ...configuradas con un funcionamiento de arranque y apagado est n equipadas con una v lvula de seguridad del interruptor de presi n Esta v lvula funciona en combinaci n con la v lvula de retenci n del ta...

Page 31: ...spu s de cada uso a fin de combatir la corrosi n interna de los mismos Mantenga cerradas las v lvulas de drenado si va a guardar la compresora durante alg n tiempo ESPECIFICACIONES OPERACI N ADVERTENC...

Page 32: ...ento de servicio al cliente en nuestra f brica si su compresora de aire que normalmente funciona de manera confiable deja de funcionar correctamente a mayor elevaci n MANTENIMIENTO Su nueva compresora...

Page 33: ...l exterior de la compresora de aire X Revisar la condici n de las almohadillas antivibraci n X Ajustar reajustar los pernos X Revisar el funcionamiento de la v lvula de seguridad X Cambiar el aceite d...

Page 34: ...er Filtro de admisi n sucio o tapado Limpie o reemplace el filtro de admisi n Anillos de pist n desgastados Lleve la unidad a reparaci n Cilindro rayado Lleve la unidad a reparaci n Ruido de golpeteo...

Page 35: ...otras las garant as de comerciabilidad y de idoneidad para un fin espec fico y todas las dem s obligaciones y o responsabilidades por parte de Associate Engineering Corporation Associate Engineering...

Reviews: