RE Start
Recording
Function: Start
recording
Syntax:
stxRE;
(RS-232C, Command format: Type 1)
Syntax:
RE
(Telnet, Command format: Type 1)
Note:
When using the RE command, you must first use the RM command to put the unit in
recording standby mode. To stop recording, use the ST command.
Recording starts when audio higher than the trigger level is input. The following four
types of trigger recording settings are available.
OFF:
Trigger recording is not performed.
LOW:
Recording starts when audio higher than -45 dB.
MID:
Recording starts when audio higher than -36 dB.
HIGH:
Recording starts when audio higher than -27 dB.
AE
Starting Time-Stamped Recording
Function: Starting Time-stamped Recording
Syntax:
stxAE:a,b,c,d,e,f,g,h,i;
(RS-232C, Command format: Type 2)
Syntax:
AE:a,b,c,d,e,f,g,h,i
(Telnet, Command format: Type 2)
a: year (1998 – 2035)
b: month (1 – 12)
c: day (1 – 31)
d: hour (0 – 23)
e: minutes (0 – 59)
f: second (0 – 59)
g: RDAC-Grade
3
32
kHz
4
44.1
kHz
5
48
kHz
6
96
kHz
h: RDAC-Mode
5 WAV-16
6 WAV-24
7 MP3-128
8 MP3-192
9 MP3-320
i: Recording Type
0 Mono
1 Stereo
Example)
AE:2014,3,1,8,59,5,4,1,0
Add a time stamp for “2014” “March” “1” “8:59:00” and start recording with “44.1 kHz”
“WAV-16” “Mono.”
Note:
The time information given in the command can be stored in the recorded phrase as a
time stamp.
The AR-3000SD starts recording immediately when it receives an AE command. However,
when you have made the trigger recording setting, the waits for audio input higher than
the trigger level (the volume level at which recording starts), then starts recording. (It is
not necessary to send an RE command. Levels in trigger recording settings may change
depending on the immediately preceding recording action and the card settings.)
The phrase number is automatically assigned to a free number where nothing is recorded.
Use the ST command to stop recording.
Also, the AR-3000SD automatically returns the total number of phrases recorded on the
card when it receives an AE command. (Refer to 4.4.1 AE command)
Caution:
The recording source of the AE command is fixed to the LINE-IN.
AR-3000SD (Ver.1.00) Command Reference - 38