Card Settings
CV
Card Name Settings
Function: Card name setting
Syntax:
stxCV:a,"b",c;
(RS-232C, Command format: Type 2)
Syntax:
CV:a,"b",c
(Telnet, Command format: Type 2)
a: Card in slot
0 Card in slot A
1 Card in slot B
2 Card in slot C
3 Card in slot D
b: Card name (up to 8 characters)
c: Reserved (Only '0')
Example)
CV:0,"ABCDEFGH",0
This specifies a name of “ABCDEFGH” for the card in slot A.
System Settings
CI
Control Input Mode Settings
Function: Control Input Mode setting
Syntax:
stxCI:a,b,c,d,e,f;
(RS-232C, Command format: Type 2)
Syntax:
CI:a,b,c,d,e,f
(Telnet, Command format: Type 2)
a: Card in slot
0 Card in slot A
1 Card in slot B
2 Card in slot C
3 Card in slot D
b: Control Input Mode
0
Direct
Play
1 Program (Count Play)
2
Binary
Play
3
Binary
REC
c: Direct Playback Method
0
Normal
1
First
In
2
Last
In
3
Sequence
d: Binary Playback Trigger Settings Level
0
Off
1
On
e: Binary Playback Trigger Settings Edge
0
Off
1
On
f: The Method used for specifying the phrase (Binary Recording)
0
Binary
1
1
Binary
2