36
4 Adjustment
4
10
Change the "Force" to 200g with [
] and [
] keys.
Then, press the [ENTER] key to move the pen DOWN.
[ ]&[ ]keys
[ENTER]key
11
Adjust VR2 on the MAIN BOARD so that the pressure would
be 199—200gf when pen tip leaves the BED.
VR2
MAIN BOARD
12
Change the pressure to "20g" again and make sure the
pressure is 26—30gf.
If not, re-adjust it.
ST-002
BED
ST-012
BED
9
Press the [ENTER] key and move the pen UP.
[ENTER] key