42
4 Adjustment
4
4-9 CALIBRATION
1
Calibration done in the factory is indicated on the sticker put
on the LEFT FRAME.
2
Put the 0.25 mm Standard Ceramic Pen to the TOOL
CARRIAGE and set A2 size paper on the machine.
4
Press [SETUP] key while pressing [
], [
] and [
] keys
to enter the SERVICE MODE.
And select "Calib." with [
] and [
] keys and press the
[ENTER] key.
LEFT FRAME
3
Move the TOOL CARRIAGE fully to the right end.
Turn power on and press the [SETUP] key within 1 second.
Summary of Contents for CAMM-1 PRO CM-300
Page 4: ... MEMO ...
Page 6: ...2 1 Structure Spare Parts 1 1 2 FRAME ...
Page 28: ...24 3 Replacement of Main Parts 3 MEMO ...
Page 62: ......
Page 63: ...CM 500 400 300 ...