49
4 Adjustment
4
6
If the clearance measured at 4 is out of 0.5—1.0 mm, press
[MENU] key and enter the KNIFE ADJUST MODE.
[MENU] key
7
In case the clearance is more than 1.0 mm, change the values
to the minus with [
] key.
In case it is less than 0.5 mm, change the value to the plus with
[
] key.
Then, press [ENTER] key to save the settings.
8
Re-check and make sure that the clearance is 0.5—1.0 mm by
carrying out the KNIFE TEST MODE.
If not, re-adjust the position.
[TEST] key
[ENTER] key
KNIFE TEST
5
Move the SEPARATING KNIFE PLATE fully to the right
with your hand and check and make sure that the clearance
with the STOPPER is 0.5—1.0 mm.
STOPPER
0.5—1.0 mm
SEPARATING
KNIFE PLATE