43
4 Adjustment
4
4-4 Function Mode
AGING MODE
Turn on the SUB POWER SW by pressing
[ ], [ ] and [ ] keys.
GRIT ROLLER and TOOL CARRIAGE
start to idle.
Turn off the SUB POWER SW to end.
PRINTING TEST
Turn on the SUB POWER SW by
pressing [CUT TEST] keys.
R
B
M
C
Y K
Cuts around C & K.
( : starting point)
C
M
Y
K
SYSTEM REPORT
Turn on the SUB POWER SW
by pressing [ ] keys.
Set Black Ribbon & Media.
Lower the Sheet Loading Lever to print.
**** PC-60 System Report ****
Version : Firmware= A140 Booter= B100
Temperature: Head= 32cel Env.= 26cel
Record : Print= 3933m Cleaning= 2
*** Factory settings ***
Offset : Head-X= -7step Head-Y= 14step Holder= -20step
Tool Force VR : Max= 776 Min= 0
Solenoid Current : Max= 41 Min= 343
Grit Distance : +8
Eccentricity : Amount- 0 Number= 0
Head ID : B06-0032
Density Adjust : +1 +1 0 0 0 0 0 0 0 0 0 0 0 0 0
: 0 0 0 0 0 0 0 0 0 0 0 -1 0 0 -1
Stitch Adjust : Upper= 0 Lower= 0
On Board Dip-SW : (1) X0XX (4)
*** User settings ***
User Dip-SW : (1) XXXXXXXXXX (10)
Line Space : 0dot
Total Printed Length
Head Temperature
Amount set by Print/Cut Offset
Adjustment
Amount set by Cartridge Position
Adjustment
Indicates the position of Slide Volume.
MAX should be bigger than MIN.
Original Amount for Current.
MAX should be smaller MIN.
Amount for Grit Compensation
Amount set by Line Space Adjustment
Eccentric amount for Grit
Eccentricity Adjustment
Amount set by Density Adjustment
DIP SW settings on Main Board
Number of cleaning with Cleaning Sheet
Environment Temperature
Serial Number of the HEAD
Amount set by Stitching Adjustment
User DIP SW settings
Summary of Contents for Color Camm Pro PC-60
Page 4: ... MEMO ...
Page 6: ...2 1 Structure Spare Parts 1 1 2 FRAME 1 ...
Page 8: ...4 1 Structure Spare Parts 1 1 3 FRAME 2 ...
Page 88: ...84 4 Adjustment 4 MEMO ...