57
4 Adjustment
4
4-10 MANUAL THERMAL HEAD DENSITY ADJUSTMENT
[THERMAL HEAD DENSITY ADJUSTMENTMODE FLOW CHART (in Factory Mode)]
The purpose of this adjustment is same as for AUTO ADJUSTMENT.
This adjustment should be performed in case of not having the data file for the HEAD or special program
for sending this data automatically.
All 30 parameters can be set manually through the panel. Parameters for the HEAD being used is
mentioned on top of the RAIL.
[SHEET TYPE] key
[ ] key
AUTO. ADJUSTMENT
MODE
Reset parameters
to default.
[CUT TEST] key
[POWER] & [FRONT COVER] LED
will blink.
MANUAL
ADJUSTMENT
MODE
RESET MODE
GROUP
SELECTION
MODE
Select GROUP to
be adjusted.
SETTING MODE
Change parameters
for HEAD DENSITY.
Save Settings.
THERMAL HEAD DENSITY
ADJUSTMENT MODE
STITCHING
ADJUSTMENT
MODE
Send data from PC.
STITCHING ADJUSTMENT
for TOP EDGE.
STITCHING ADJUSTMENT
for BOTTOM EDGE.
Change parameters for TOP
STITCHING ADJUSTMENT.
Change parameters for BOTTOM
STITCHING ADJUSTMENT.
Save Settings.
Save Settings.
[POWER] key
[ ] key
[ ] or [ ] keys
[ ] or [ ] keys
[SHEET TYPE] key
[CUT TEST] key
[COLOR] LED will be ON.
[ ] key
[SHEET TYPE] key
[CARTRIDGE HOLDER 1, 3 & 5] and
[CARTRIDGE HOLDER 2, 4 & 6] will
blink alternately.
[BASE POINT] key
[ ] or [ ] keys
[BASE POINT] key
[ ] or [ ] keys
[SHEET TYPE] key
[BASE POINT] LED will
be ON.
[BASE POINT] LED will
be OFF.
[POWER] & [BASE POINT] LED
will blink.
After all [CARTRIDGE HOLDER] LED
become ON, it will be turned OFF from 1 to 6 in order.
Then, [PIECE] and [ROLL] LED will be ON.
For selection
1
To enter
Turn on the MAIN POWER SW while pressing [POWER],
[SHEET TYPE] and [BASE POINT] keys and enter the
FACTORY MODE.
Select [CARTRIDGE HOLDER 5] with [
] or [
] keys
and press [SHEET TYPE] key to enter the THERMAL
HEAD DENSITY ADJUSTMENT MODE.
Summary of Contents for Color Camm Pro PC-60
Page 4: ... MEMO ...
Page 6: ...2 1 Structure Spare Parts 1 1 2 FRAME 1 ...
Page 8: ...4 1 Structure Spare Parts 1 1 3 FRAME 2 ...
Page 88: ...84 4 Adjustment 4 MEMO ...