18
Dec.2004
SYSTEM SOFTWARE
UPDATING INSTRUCTIONS
Required items
*
In order to play back the update data, you will need a means to play back SMF
data.
We recommend a co UM-2 + UpdSMF.exe (UpdSMFJ.exe).
In the explanation that follows, we assume that you are using a co
UM-2 + UpdSMF.exe (UpdSMFJ.exe).
1.
SMF data for the update CD-ROM (#17041565)
_0000001.mid - _0000021.mid
2.
SMF playback system
•
Computer with USB connector (the UM-2 driver must be installed)
•
UM-2
•
UpdSMF.exe (English version) or UpdSMFJ.exe (Japanese version)
3.
Adaptor BRC series
4.
MIDI cable
Update procedure
*
As a precaution, please make a backup of the user data before you continue.
1.
Connect the MIDI OUT 1 (or 2) of your MIDI playback system (computer
+ UM-2) to the DR-880’s MIDI IN.
2.
While holding down [SHIFT] + [EDIT], power-on the DR-880.
fig.system1
3.
Start up UpdSMF.exe (UpdSMFJ.exe), and make the following settings.
MIDI Out Device =1: EDIROL UM-2 MIDI 1 (or 2)
SMF Path =
the directory that contains the update SMF data
4.
Click Scan SMF.
Verify that you see the update data (_0000001.mid - _0000021.mid).
5.
Click Send.
The update will begin.
*
Don’t turn off the power during the update. Doing so may destroy the user
memory.
During the update, the following screens will alternate. The FAVORITE [1]-[4]
button LEDs will blink.
fig.system2
fig.system3
6.
When the update is finished, the following display will appear.
Verify the checksum (Prg1, Prg2).
fig.system4
7.
Power-off the DR-880.
TEST MODE
Required items
1.
Oscillator
2.
Oscilloscope
3.
Monitor amp
4.
Noise meter
5.
Ammeter
6.
FS-5U
7.
EV-5
8.
D/A converter
9.
Computer
Supported OS: Windows XP/2000/Me or later
10.
MIDI cable
11.
USB cable
Preparations for test mode
•
Oscilloscope settings
TIME/DIV: 1 [msec]
VOLT/DIV: 2 [V]
•
Oscillator
1.
Waveform: square wavefrequency: 200 [Hz], amplitude: 100 [mVp-p]
2.
Waveform: sine wavefrequency: 200 [Hz], amplitude: -10 [dBu]
•
Noise meter
FILTER: JIS-A
•
FS-5U
Set the POLARITY switch toward the jack.
•
EV-5
Set the MIN VR to “0”
•
DR-880
GUITAR/BASS INPUT VR = MAX
DRUM VR = MAX
BASS VR = MAX
MASTER VR = MAX
Flash-ROM Updater
CPU
1.00 0007 2004/05/13
EXT
1.00 0103 2004/09/27
Flash-ROM Updater
adrs 0x00******
Receiving...
Flash-ROM Updater
adrs 0x00******
sum 0x****
Waiting...
Flash-ROM Updater
adrs 0x0044FFF0
sum 0x****
Completed.
sum(prg1)0x****
sum(prg2)0x****
Summary of Contents for DR-880
Page 11: ...11 DR 880...
Page 29: ...31 Dec 2004 DR 880 CIRCUIT BOARD MAIN BOARD fig b main1 eps View from components side...
Page 30: ...33 Dec 2004 DR 880 CIRCUIT BOARD MAIN BOARD fig b main2 eps View from foil side...
Page 34: ...41 Dec 2004 DR 880 CIRCUIT BOARD SW fig b sw1 eps View from components side...
Page 35: ...43 Dec 2004 DR 880 CIRCUIT BOARD SW fig b sw2 eps View from foil side...