16
After Plotting
Care and
Maintenance
1. Remove the paper.
DXY-1350A: Press the
[PAPER HOLD]
key to release the electrostatic adsorption and remove the
paper.
DXY-1150A: Remove the paper clip, release the metal strips, and remove the paper.
2. Turn off the DXY.
Switch off the power to the DXY. If the plotter will not be used for a long time, the electrical
cord should also be unplugged.
3. Remove the pens.
Remove all pens from the pen stock. Cap and store the pens after use.
Be sure to turn off the power to the DXY before cleaning.
Never attempt to oil or lubricate the mechanism.
The drawing board for the DXY-1350A is an electrostatic pad. When cleaning the drawing board,
never use water, silicone cloth, neutral detergent, solvent, or chemically-treated cloth. Such materials
can permanently degrade the board's electrostatic adhesive force.
Cleaning the Main Unit
If the unit becomes dirty, wipe gently using a cloth moistened with water or anhydrous alcohol.
Cleaning the Drawing Board
Gently wipe with a soft cloth. If soiling is severe or the adsorptive force of the drawing board is weak
(DXY-1350A only), wipe gently using a cloth moistened with ethyl alcohol. The DXY-1350A use an
electrostatic adsorption drawing board, which must never come in contact with water, neutral detergents,
solvents, silicone cloth, or any other type of chemically treated wiper cloths, as these will irrevocably
diminish the electrostatic adsorptive force.
Cleaning the Pen Cap Rubbers
Ink buildup on the pen cap rubbers may soil plots. Remove the pen cap rubbers and wash with water.
Replace them on the pen stock after allowing to dry completely (out of direct sunlight).