7
FAST
POWER
ERROR
POWER/ERROR
LED
Lights up when the power is turned on. This LED
also blinks when an error has occurred.
On the DXY-1150A, only the pen
number is shown. The following
functions are available only on the
DXY-1350A.
[VIEW]
key
Moves the carriage to the upper right of the
drawing board and pauses operation. Pressing the
key a second time return the pen carriage to the
pen position it was at immediately before.
VIEW
LED
Lights up during VIEW
,
,
and
position keys
Moves the pen carriage. Pressing two adjacent
position keys at the same moves the pen carriage
diagonally.
[FAST]
key
Pressing this key speeds up carriage movement.
[REPLOT]
key (DXY-1350A only)
Press this key while the REPLOT MODE LED is lit to
execute replotting.
REPLOT
LED (DXY-1350A only)
Lights up when replotting is possible.
[REPLOT MODE]
key (DXY-1350A only)
Switches to the Replot mode. (See "Explanation of
Functions and Operation".)
[PAPER HOLD]
key (DXY-1350A only)
Causes paper to stick to the drawing board.
PAPER HOLD
LED (DXY-1350A only)
Lights up during paper hold.
[PEN UP/DOWN]
key
Press this key to move the pen up or down.
[ENTER]
key
Use this key in combination with other keys to operate
the DXY.
[P1]
and
[P2]
scaling point keys
Pressing the
[P1]
or
[P2]
key moves the pen
carriage to the specified position. (See "Explana-
tion of Functions and Operation".)
Control Panel
PEN
SPEED
PEN SELECT
8
420mm/sec
7
220mm/sec
6
160mm/sec
5
120mm/sec
4
90mm/sec
3
60mm/sec
2
40mm/sec
1
30mm/sec
[PEN SPEED]
key
Pen speed can be set by pressing
this key and the
1
30mm/sec
key. (See
"Pens".)
PEN
SPEED
1
30mm/sec
8
420mm/sec
[PENSELECT]
key
The pen to be used can be
selected while this key is held