70
Use MIDI functionality
Advanced mode 2
Advanced mode 2 simulates the operation of a conventional rotary encoder. If this is assigned
to a controller, moving that controller toward the right (upward) of center will have the same
effect as turning the encoder clockwise, and moving the controller toward the left (downward)
of center will have the same effect as turning the encoder counterclockwise. As the controller is
moved further away from the center, the result will be the same as if the rotary encoder were
moved more quickly.
You can assign advanced mode 2 to a button, but it will not function.
1.
Press the
[EDIT]
button.
2.
Slightly move the controller to which you want to assign a Control Change message.
The display will indicate the number of the selected controller.
3.
Confirm what’s indicated, and press the
[ENTER]
button.
4.
Using the
ASSIGNABLE FUNCTION
keys (
) on the keyboard, get "CC0" to appear
in the display, then press the
[2]
key of the keyboard.
The display will indicate “CC2”.
5.
Press the
[ENTER]
button.
6.
Input the channel.
7.
Press the
[ENTER]
button.
8.
Input the control change number. Use the
[DEC] [INC]
buttons or the
[0]
–
[F]
keys to
specify the control change number.
fig.p
9.
Press the
[ENTER]
button.
The display will indicate “P–”.
10.
Specify the output port. (
➝
*1 Reference
*1 The -- area displays the currently set value. If it has not been set, the default setting will be displayed. Even if you change the type or mode
of the MIDI message that is assigned, the default setting will be displayed. This will be lit if the value is the same as the currently set value,
or will blink if the value is different.